Microwave Radiometer Calibration Using Deep Learning With Reduced Reference Information and 2-D Spectral Features
Open Access
- 15 November 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 748-765
Abstract
The accuracy of geophysical retrievals from radiometers relies on calibration quality, encompassing both absolute radiometric accuracy and spectral consistency. Radiometers have employed various calibration techniques, including external targets, vicarious sources, and internal calibrators like noise diodes or matched reference loads. Calibration techniques face challenges like frequency dependence, instrumental effects, environmental influences, drift, aging, and radio frequency interference. Recent hardware advancements enable radiometers to collect raw samples containing both temporal and spectral information. Leveraging advanced modeling techniques like deep learning (DL) enables detecting subtle correlations, non-linear dependencies, and higher-order interactions within the data extracting valuable information that may have been challenging with conventional methods. This study utilizes NASA's Soil Moisture Active Passive (SMAP) satellite's level 1A and level 1B data products to develop a DL-based radiometer calibrator to estimate antenna temperature. Spectrograms of second raw moments equivalent to power carrying the 2-D spectral features serve as primary input in a supervised convolutional neural network-based architecture. DL-based calibrator has demonstrated high correlation and low root mean square error when incorporating spectral information from both reference and noise diodes and when not considering this information. Findings suggest that the ancillary features such as internal thermistor temperature and loss elements exhibit sufficient accuracy in estimating antenna temperature to compensate for variations in receiver noise temperature and short-term gain fluctuations in the absence of the reference load and noise diode power. The proposed calibration technique with reduced reference information might enable radiometers for a higher number of antenna scene observations within a footprint.Keywords
Funding Information
- National Science Foundation (2030291, 2047771)
- Jet Propulsion Laboratory, California Institute of Technology
- National Aeronautics and Space Administration (80NM0018D0004)
This publication has 40 references indexed in Scilit:
- Aquarius L-Band Microwave Radiometer: 3 Years of Radiometric Performance and Systematic EffectsIEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing, 2015
- One Year of Surface-Based Temperature Inversions at Dome C, AntarcticaBoundary-Layer Meteorology, 2013
- The challenges in long-term altimetry calibration for addressing the problem of global sea level changeAdvances In Space Research, 2013
- On Early Stopping in Gradient Descent LearningConstructive Approximation, 2007
- Evaluation of the Amazon Rain Forrest as a Distributed Target for Satellite Microwave Radiometer Calibration2006
- Determination of an Amazon Hot Reference Target for the On-Orbit Calibration of Microwave RadiometersJournal of Atmospheric and Oceanic Technology, 2005
- Characterization and correction of a drift in calibration of the TOPEX microwave radiometerIEEE Transactions on Geoscience and Remote Sensing, 2002
- Detection of calibration drifts in spaceborne microwave radiometers using a vicarious cold referenceIEEE Transactions on Geoscience and Remote Sensing, 2000
- ESTAR: a synthetic aperture microwave radiometer for remote sensing applicationsProceedings of the IEEE, 1994
- Interferometric synthetic aperture microwave radiometry for the remote sensing of the EarthIEEE Transactions on Geoscience and Remote Sensing, 1988