Noninvasive Glucose Monitoring
Authors:
- Satish GargSGSatish Garg
- Lois JovanovicLJLois Jovanovic
- Kenneth R. PitzerKPKenneth R. Pitzer
- Steve FermiSFSteve Fermi
- Russell O. PottsRPRussell O. Potts
- the Cygnus Research TeamTTthe Cygnus Research Team
- 17 November 1999
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA
- Vol. 282 (19) , 1839-1844
Abstract
Research from JAMA — Noninvasive Glucose Monitoring — Comprehensive Clinical Results — ContextIntensive diabetes management using frequent blood glucose measurements to guide therapy has been shown to significantly improve short- and long-term outcomes. Development of a device that makes possible frequent, automatic, painless, and accurate measurements of glucose would facilitate intensive management.ObjectiveTo determine the accuracy of the GlucoWatch automatic glucose biographer (Cygnus Inc) compared with that of serial blood glucose measurements.DesignMulticenter comparative study of the GlucoWatch biographer and the HemoCue blood glucose analyzer (Aktiebolaget Leo) performed between August 29 and October 17, 1998. Participants wore up to 2 biographers during the 15-hour study session and performed 2 fingersticks per hour for comparative blood glucose measurements. The biographers were calibrated with a single HemoCue measurement after a 3-hour warm-up period. Diet and insulin were manipulated to produce a broad glycemic range during the study.SettingControlled clinical environment at 2 diabetes centers and 3 contract research organizations in the United States.ParticipantsA total of 92 subjects (mean [SD] age, 42.1 [15.1] years; 59.8% women) with type 1 or 2 diabetes requiring treatment with insulin.Main Outcome MeasuresMean error, mean absolute error, correlation, slope, and intercept using Deming regression, and clinical significance of differences between biographer readings and blood glucose measurements using the Clarke error grid.ResultsResults showed close tracking of blood glucose over a range of 2.2 to 22.2 mmol/L (40-400 mg/dL) for up to 12 hours using a single point calibration. The biographer readings lagged behind serial blood glucose values by a mean of 18 minutes. An analysis of 2167 data pairs shows a linear relationship (r = 0.88; slope = 1.03; intercept = −0.33 mmol/L [−6 mg/dL]) between biographer readings and serial glucose measurements. The mean absolute error between the 2 measurements was 15.6% (mean error [SD], −0.07 [1.82] mmol/L [−1 {33} mg/dL]), and 96.8% of the data fell in the therapeutically relevant regions of the error grid analysis.ConclusionThese results demonstrate close agreement between GlucoWatch biographer readings and blood glucose measurements using repeated fingerstick blood samples. The automatic, frequent, and noninvasive measurements obtained with the biographer provides more information about glucose levels than the current standard of care.Keywords
This publication has 13 references indexed in Scilit:
- Design and Simulation of a Reverse Iontophoretic Glucose Monitoring DeviceJournal of the Electrochemical Society, 1998
- Validation of Home Blood Glucose Meters With Respect to Clinical and Analytical ApproachesDiabetes Care, 1998
- Self-Monitoring of Blood Glucose in Type I Diabetic Patients: Comparison With Continuous Microdialysis Measurements of Glucose in Subcutaneous Adipose Tissue During Ordinary Life ConditionsDiabetes Care, 1997
- Accuracy of home blood glucose meters during hypoglycemiaDiabetes Care, 1996
- Reverse Iontophoresis: Noninvasive Glucose Monitoring in Vivo in HumansPharmaceutical Research, 1995
- Measurement of glucose in diabetic subjects using noninvasive transdermal extractionNature Medicine, 1995
- Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin-dependent diabetes mellitus: a randomized prospective 6-year studyDiabetes Research and Clinical Practice, 1995
- On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysisDiabetologia, 1992
- Noninvasive Sampling of Biological Fluids by IontophoresisPharmaceutical Research, 1989
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987