Assessment of Automated Disease Detection in Diabetic Retinopathy Screening Using Two-Field Photography
Authors:
Open Access
- 8 December 2011
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (12) , e27524
Abstract
To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of both eyes were acquired and independently graded according to the English national grading scheme. Where discrepancies were found between the automated result and original manual grade, internal and external arbitration was used to determine the final study grades. Two versions of the software were used: one that detected microaneurysms alone, and one that detected blot haemorrhages and exudates in addition to microaneurysms. Results for each version were calculated once using both fields and once using the macula-centred field alone. Of the 8,271 episodes, 346 (4.2%) were considered unassessable. Referable disease was detected in 587 episodes (7.1%). The sensitivity of the automated system for detecting unassessable images ranged from 97.4% to 99.1% depending on configuration. The sensitivity of the automated system for referable episodes ranged from 98.3% to 99.3%. All the episodes that included proliferative or pre-proliferative retinopathy were detected by the automated system regardless of configuration (192/192, 95% confidence interval 98.0% to 100%). If implemented as the first step in grading, the automated system would have reduced the manual grading effort by between 2,183 and 3,147 patient episodes (26.4% to 38.1%). Automated grading can safely reduce the workload of manual grading using two field, mydriatic photography in a routine screening service.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of a Computer-Aided Diagnosis System for Diabetic Retinopathy Screening on Public DataInvestigative Ophthalmology & Visual Science, 2011
- Automated grading for diabetic retinopathy: a large-scale audit using arbitration by clinical expertsBritish Journal of Ophthalmology, 2010
- Ocular anaesthesia and the never-ending storyBritish Journal of Ophthalmology, 2009
- Diabetic macular oedema and visual loss: relationship to location, severity and durationActa Ophthalmologica, 2009
- The role of haemorrhage and exudate detection in automated grading of diabetic retinopathyBritish Journal of Ophthalmology, 2009
- Long‐term impact of retinal screening on significant diabetes‐related visual impairment in the working age populationDiabetic Medicine, 2009
- The efficacy of automated "disease/no disease" grading for diabetic retinopathy in a systematic screening programmeBritish Journal of Ophthalmology, 2007
- Effect of Ruboxistaurin on Visual Loss in Patients with Diabetic RetinopathyOphthalmology, 2006
- Interobserver Agreement in the Interpretation of Single-Field Digital Fundus Images for Diabetic Retinopathy ScreeningOphthalmology, 2006
- Sensitivity and specificity of photography and direct ophthalmoscopy in screening for sight threatening eye disease: the Liverpool diabetic eye studyBMJ, 1995