Partial Fourier transform reconstruction for single‐shot MRI with linear frequency‐swept excitation
Open Access
- 15 June 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (5) , 1326-1336
Abstract
A novel image encoding approach based on linear frequency‐swept excitation has been recently proposed to overcome artifacts induced by various field perturbations in single‐shot echo planar imaging. In this article, we develop a new super‐resolved reconstruction method for it using the concepts of local k‐space and partial Fourier transform. This method is superior to the originally developed conjugate gradient algorithm in convenience, image quality, and stability of solution. Reduced field‐of‐view is applied to the phase encoding direction to further enhance the spatial resolution and field perturbation immunity of the image obtained. Effectiveness of this new combined reconstruction method is demonstrated with a series of experiments on biological samples. Two single‐shot sequences with different encoding features are tested. The results show that this reconstruction method maintains excellent field perturbation immunity and improves fidelity of the images. In vivo experiments on rat indicate that this solution is favorable for ultrafast imaging applications in which severe susceptibility heterogeneities around the tissue–air or tissue–bone interfaces, motion and oblique plane effects usually compromise the echo planar imaging image quality. Magn Reson Med, 2013.Keywords
This publication has 35 references indexed in Scilit:
- Spatiotemporal encoding as a robust basis for fast three‐dimensional in vivo MRINMR in Biomedicine, 2011
- Functional magnetic resonance imaging using RASERNeuroImage, 2011
- Robust EPI Nyquist ghost elimination via spatial and temporal encodingMagnetic Resonance in Medicine, 2010
- Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fieldsMagnetic Resonance in Medicine, 2010
- Simultaneous fMRI and local field potential measurements during epileptic seizures in medetomidine‐sedated rats using raser pulse sequenceMagnetic Resonance in Medicine, 2010
- Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulsesJournal of Magnetic Resonance Imaging, 2010
- High fidelity magnetic resonance imaging by frequency sweep encoding and Fourier decodingJournal of Magnetic Resonance, 2010
- O‐space imaging: Highly efficient parallel imaging using second‐order nonlinear fields as encoding gradients with no phase encodingMagnetic Resonance in Medicine, 2010
- RASER: A new ultrafast magnetic resonance imaging methodMagnetic Resonance in Medicine, 2007
- Image distortion correction in EPI: Comparison of field mapping with point spread function mappingMagnetic Resonance in Medicine, 2002