The potentiometric and impedance characteristics of various selective Ca2+ polymeric membranes are described and interpreted by theory and experiments for Ca2+ microfabricated sensor arrays. These are designed for further biomedical applications with an emphasis on potential in situ applications. The polymeric materials used in the present studies consist of either carboxylated PVC or aliphatic polyurethane. Both materials showed good adherence properties to the polyimide-coated Kapton substrate used in planar sensor fabrication. The impedance analysis, performed in the frequency range from 65,000 Hz to 0.1 Hz, revealed the bulk geometrical response at high frequencies. Measured Rbulk corresponds to the unperturbed bulk resistance. That, in turn, depends on mobilities and concentrations of Ca2+ complex and mobile sites. Decreases in Rbulk correlated well with sensor behavior during the preconditioning (hydration) period. Studies of blood interactions with these sensors proved that the main sensor characteristics (E0, slope of the calibration curve, and reproducibility of response) are not significantly affected after 14 days of whole blood contact.Keywords
This publication has 21 references indexed in Scilit:
- Microfabricated Sensor Arrays Sensitive to pH and K+ for Ionic Distribution Measurements in the Beating HeartAnalytical Chemistry, 1995
- Ion-Selective Microchemical Sensors with Reduced Preconditioning Time. Membrane Biostability Studies and Applications in Blood AnalysisAnalytical Letters, 1994
- Carboxylated Poly(vinyl chloride) as a Substrate for Ion Sensors: Effects of Native Ion Exchange on ResponsesAnalytical Chemistry, 1994
- Planar micro sensors for in vivo myocardial pH measurementsTalanta, 1994
- Ion‐selective membranes with low plasticizer content: Electroanalytical characterization and biocompatibility studiesJournal of Biomedical Materials Research, 1994
- Electroanalytical and biocompatibility studies on carboxylated poly(vinyl chloride) membranes for microfabricated array sensorsThe Analyst, 1994
- In vivo and in vitro testing of microelectronically fabricated planar sensors designed for applications in cardiologyAnalytical and Bioanalytical Chemistry, 1993
- Flexible (Kapton-based) microsensor arrays of high stability for cardiovascular applicationsJournal of the Chemical Society, Faraday Transactions, 1993
- Electrochemical performance, biocompatibility, and adhesion of new polymer matrixes for solid-state ion sensorsAnalytical Chemistry, 1991
- Elimination of the asymmetry in neutral-carrier based solvent polymeric membranes induced by proteinsAnalytical Chemistry, 1988