Interactive continuously moving table (iCMT) large field‐of‐view real‐time MRI
- 3 April 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (5) , 1202-1209
Abstract
Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field‐of‐view (FOV) images by acquiring readouts along the patient superior–inferior axis as the subject is translated through the scanner. For applications that require artifact‐free images, such as arterial‐phase contrast‐enhanced (CE) angiography of the legs, a major challenge is to match the MR data acquisition and patient table motion with the dynamics of blood flow in the region of interest (ROI). Instead of restricting the CMT to predetermined constant table speeds, we adopted a more general approach in which the table motion is decoupled from the phase‐encoding order. In our approach the table moves adaptively and in response to operator‐provided feedback obtained from viewing real‐time preview (or fluoroscopic) images. This interactivity is accomplished by integrating high temporal‐spatial resolution encoding of the table position with real‐time hybrid‐space filling and image reconstruction. Experimental results obtained using our prototype interactive CMT (iCMT) system on a peripheral vascular phantom and five healthy volunteers demonstrate the feasibility of this robust and rapid imaging method for acquiring 3D large‐FOV continuous images with patient‐specific adaptive table motion profiles. Magn Reson Med, 2006.Keywords
This publication has 27 references indexed in Scilit:
- Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedbackMagnetic Resonance in Medicine, 2005
- Variable field of view for spatial resolution improvement in continuously moving table magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- Continuously moving table SENSE imagingMagnetic Resonance in Medicine, 2004
- Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motionMagnetic Resonance in Medicine, 2004
- Use of a three‐station phased array coil to improve peripheral contrast‐enhanced magnetic resonance angiographyJournal of Magnetic Resonance Imaging, 2004
- Correction for gradient nonlinearity in continuously moving table MR imagingMagnetic Resonance in Medicine, 2004
- Time-resolved 3D contrast-enhanced MRA of an extended FOV using continuous table motionMagnetic Resonance in Medicine, 2004
- High Spatial Resolution Whole-Body MR Angiography Featuring Parallel Imaging: Initial ExperienceRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Helical MR: Continuously moving table axial imaging with radial acquisitionsMagnetic Resonance in Medicine, 2003
- Extended field-of-view imaging with table translation and frequency sweepingMagnetic Resonance in Medicine, 2003