Sensing Performance of a New Wireless Implantable Loop Recorder: A 12-Month Follow Up Study
Authors:
- Sony JacobSJSony Jacob
- Naga V. A. KommuriNKNaga V. A. Kommuri
- Sandip K. ZalawadiyaSZSandip K. Zalawadiya
- Marc D. MeissnerMMMarc D. Meissner
- Randy A. LiebermanRLRandy A. Lieberman
- 28 January 2010
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (7) , 834-840
Abstract
The implantable loop recorder (ILR) is a cost-effective tool with a high diagnostic yield in the evaluation of unexplained recurrent syncope. The Sleuth ILR (Transoma Medical, St. Paul MN, USA) is a new-generation ILR with wireless transmission capability approved by the Food and Drug Administration. We report the feasibility of achieving appropriate sensing over 1-year follow-up at the traditional midclavicular and alternative inframammary implantation sites without preimplant electrocardiogram (ECG) mapping. We studied 32 patients with unexplained syncope, aged 58.4+/-18.44 years, with an ILR implanted at the left midclavicular location (n = 17) or the left inframammary site (n = 15) over 1-year post implant. No preimplant electrocardiogram (ECG) mapping was performed. The highest R-wave amplitudes were observed at the inframammary site, but over the entire follow-up period, amplitudes were not significantly different from those at the midclavicular site. At both sites, R-wave amplitudes at the 6-month follow-up were significantly higher than those measured at 1 week. P-waves were visible in 80-90% of the patients. There was no discernible difference in P-waves (amplitude) relative to implant location. Body mass index, left ventricular ejection fraction, and age did not significantly influence the R-wave amplitude or the ability to discern P-waves. Our findings show that the Sleuth ILR implanted at both the midclavicular and inframammary locations without preimplant ECG mapping achieves acceptable "R" waves. This may simplify implantation procedures and improve patient satisfaction.Keywords
This publication has 10 references indexed in Scilit:
- Use of implantable loop recorders in the diagnosis and management of syncope*1European Heart Journal, 2004
- Arrhythmia Detection by Patient and Auto-Activation in Implantable Loop RecordersJournal of Interventional Cardiac Electrophysiology, 2004
- A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncopeThe American Journal of Medicine, 2003
- How Can We Identify the Best Implantation Site for an ECG Event Recorder?Pacing and Clinical Electrophysiology, 2000
- Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorderEP Europace, 2000
- An welcher Stelle soll ein implantierbarer EKG-Event-Recorder plaziert werden?Clinical Research in Cardiology, 2000
- The high cost of syncope: Cost implications of a new insertable loop recorder in the investigation of recurrent syncopeAmerican Heart Journal, 1999
- Implantable loop recorder: evaluation of unexplained syncopeHeart, 1999
- Use of an Extended Monitoring Strategy in Patients With Problematic SyncopeCirculation, 1999
- Maturation of the Sensed Electrogram Amplitude Over Time in a New Subcutaneous Implantable Loop RecorderPacing and Clinical Electrophysiology, 1997