Real-time Assessment of Right and Left Ventricular Volumes and Function in Patients with Congenital Heart Disease by Using High Spatiotemporal Resolution Radial k-t SENSE
Authors:
- Vivek MuthuranguVMVivek Muthurangu
- Philip LurzPLPhilip Lurz
- Jeffery D. CritchelyJCJeffery D. Critchely
- John E. DeanfieldJDJohn E. Deanfield
- Andrew M. TaylorATAndrew M. Taylor
- Michael S. HansenMHMichael S. Hansen
- 1 September 2008
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 248 (3) , 782-791
Abstract
The purpose of this study was to compare ventricular volumes in patients with congenital heart disease measured by using (a) a cardiac gated sequence, (b) a standard real-time sequence, and (c) a radial real-time k-space and time (k-t) sensitivity encoding (SENSE) sequence. The local research ethics committee approved this study, and written consent was obtained from all participants. Of 40 patients with congenital heart disease, ventricular volumes were measured by using the three sequences. Global image quality and motion fidelity were scored and compared with a Wilcoxon signed rank test. Image contrast, edge sharpness, and summed perimeters (the total length of the endocardial tracings for a given ventricle at systole and diastole) were quantified and compared by using paired t tests. Ventricular volumes were compared with paired t tests, Bland-Altman analysis, and correlation coefficients. Global image quality, motion fidelity, image contrast, edge sharpness, and summed perimeters were all greater for radial real-time k-t SENSE imaging compared with standard real-time imaging (P < .05). However, the gated acquisitions were significantly superior to radial real-time k-t SENSE (P < .05). For cardiac gated versus radial k-t real-time acquisitions, there was no difference between right ventricular (RV) volumes and ejection fraction (EF) (P > .15). There was a small difference in left ventricular (LV) end-diastolic volume (EDV) and thus, LV stroke volume and EF (P < .05). For cardiac gated versus standard real-time acquisitions, both RV and LV EDV and thus, stroke volume and EF were significantly lower (P < .05). Ventricular volumes and function can be accurately quantified by using radial k-t SENSE real-time imaging.Keywords
This publication has 18 references indexed in Scilit:
- Preoperative Thresholds for Pulmonary Valve Replacement in Patients With Corrected Tetralogy of Fallot Using Cardiovascular Magnetic ResonanceCirculation, 2007
- Validation and Application of Single Breath-Hold Cine Cardiac MR for Ventricular Function Assessment in Children with Congenital Heart Disease at Rest and During Adenosine Stress#Journal of Cardiovascular Magnetic Resonance, 2005
- Assessment of Myocardial Function with Interactive Non–Breath-hold Real-time MR Imaging: Comparison with Echocardiography and Breath-hold Cine MR ImagingRadiology, 2004
- Quantitative Assessment of Left Ventricular Function with Interactive Real-Time Spiral and Radial MR ImagingRadiology, 2003
- Rapid Evaluation Of Right And Left Ventricular Function And Mass Using Real-time True-fisp Cine Mr Imaging Without Breath-hold: Comparison With Segmented True-fisp Cine Mr Imaging With Breath-holdJournal of Cardiovascular Magnetic Resonance, 2003
- Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophyThe American Journal of Cardiology, 2002
- Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging systemJACC, 2001
- Measurements of left ventricular dimensions using real-time acquisition in cardiac magnetic resonance imaging: comparison with conventional gradient echo imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 2001
- Quantification of left ventricular function with magnetic resonance images acquired in real timeJournal of Magnetic Resonance Imaging, 2000
- Function: Magnetic Resonance Real-Time Imaging for the Evaluation of Left Ventricular FunctionJournal of Cardiovascular Magnetic Resonance, 2000