The aim of this study is to evaluate the performance of a new computed tomography‐dual energy analysis (CT‐DEA) technique developed for the non‐invasive assessment of the 3D spatial distribution of calcium/phosphorus (Ca/P) ratio in bone. For this, the Ca/P ratio in 58 regions from four healthy and four inflammation‐mediated osteoporotic (IMO) rabbit bone collagen‐free samples were assessed using energy dispersive X‐ray spectroscopy (EDX) and CT‐DEA. Image registration, performed using NifTK software (Centre for Medical Imaging Computing, University College London), allowed the comparison with the results from the two imaging systems. A value of R 2 =0.69 in the fit of CT‐DEA Ca/P ratio versus EDX Ca/P ratio and a mean absolute/percentage difference of 0.11 ± 0.08/8 ± 6 % in the CT‐DEA Ca/P ratio from the EDX results suggest sufficient confidence in the current experimental capabilities of the developed technique. The main difficulties in the comparison of the results using the two techniques and possible sources of error are discussed. Even though there are still possible improvements that can be made in the developed technique, through this study, it has been shown that CT‐DEA can provide valuable 3D, non‐invasive information on the comparison between healthy and osteoporotic bone. © 2014 The Authors. X‐Ray Spectrometry published by John Wiley & Sons, Ltd.Keywords
Funding Information
- University College London
- Engineering and Physical Sciences Research Council
This publication has 18 references indexed in Scilit:
- A new technique for the assessment of the 3D spatial distribution of the calcium/phosphorus ratio in bone apatitePhysiological Measurement, 2013
- Infrared spectroscopic assessment of the inflammation-mediated osteoporosis (IMO) model applied to rabbit boneJournal of Biological Physics, 2012
- Ca/P concentration ratio at different sites of normal and osteoporotic rabbit bones evaluated by Auger and energy dispersive X-ray spectroscopyJournal of Biological Physics, 2011
- Accurate determination of the Ca:P ratio in rough hydroxyapatite samples by SEM‐EDS, PIXE and RBS—a comparative studyX-Ray Spectrometry, 2009
- New imaging technologies in the diagnosis of osteoporosisReviews in Endocrine and Metabolic Disorders, 2006
- High resolution Ca/P maps of bone architecture in 3D synchrotron radiation microtomographic imagesApplied Radiation and Isotopes, 2005
- Inaccuracies Inherent in Dual-Energy X-Ray Absorptiometry In Vivo Bone Mineral Density Can Seriously Mislead Diagnostic/Prognostic Interpretations of Patient-Specific Bone FragilityJournal of Bone and Mineral Research, 2001
- Evaluation of the Ca/P concentration ratio in hydroxyapatite by STEM-EDXS: influence of the electron irradiation dose and temperature processingJournal of Physics D: Applied Physics, 2000
- An Update on the Diagnosis and Assessment of Osteoporosis with DensitometryOsteoporosis International, 2000
- An electron probe X-ray microanalytical study of bone mineral in osteogenesis imperfectaCalcified Tissue International, 1995