Fractional-slot concentrated-winding axial-flux permanent magnet machine with core-wound coils
- 1 September 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 1066-1073
Abstract
This paper presents the design, finite element analysis (FEA) and experimental verification of a single stator double rotor fractional-slot concentrated-winding (FSCW) axial-flux permanent magnet (AFPM) machine, with core-wound coils. The advantages that are obtained by adopting such coil construction, in terms of shorter end-winding connections, higher fill factor and mechanical robustness of the magnetic structure are highlighted. Machine performances both at no load and at rated load are analyzed through static FEA and a simple index is introduced, in order to compare induced losses in the permanent magnets for various machine configurations. The construction and experimental testing of a full scale prototype is described, in order to confirm the expected performances and to characterize the prototype in terms of losses, cogging torque and main machine parameters.Keywords
This publication has 12 references indexed in Scilit:
- Influence of magnetic wedges on the no-load performance of axial flux permanent magnet machines2010
- Fractional-Slot Concentrated-Windings Synchronous Permanent Magnet Machines: Opportunities and ChallengesIEEE Transactions on Industrial Electronics, 2009
- Concentrated winding axial flux permanent magnet motor with plastic bonded magnets and sintered segmented magnets2008
- Design Issues Of A Fractional-Slot Windings Axial Flux PM Machine With Soft Magnetic Compound Stator2007
- Impact of Winding Layer Number and Magnet Type on Synchronous Surface PM Machines Designed for Wide Constant-Power Speed Range Operation2007 IEEE Industry Applications Annual Meeting, 2006
- Application of Direct-Drive Wheel Motor for Fuel Cell Electric and Hybrid Electric Vehicle Propulsion SystemIEEE Transactions on Industry Applications, 2006
- Comparison of PM brushless motors, having either all teeth or alternate teeth woundIEEE Transactions on Energy Conversion, 2006
- Design and operation aspects of field regulated PM synchronous machines with concentrated armature windings2005
- Experimental Study on Reducing Cogging Torque and No-Load Power Loss in Axial-Flux Permanent-Magnet Machines With Slotted WindingIEEE Transactions on Industry Applications, 2004
- Synthesis of high performance PM motors with concentrated windingsIEEE Transactions on Energy Conversion, 2002