Central venous pressure estimation from ultrasound assessment of the jugular venous pulse
Authors:
Open Access
- 28 October 2020
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (10) , e0240057
Abstract
Acquiring central venous pressure (CVP), an important clinical parameter, requires an invasive procedure, which poses risk to patients. The aim of the study was to develop a non-invasive methodology for determining mean-CVP from ultrasound assessment of the jugular venous pulse. In thirty-four adult patients (age = 60 ± 12 years; 10 males), CVP was measured using a central venous catheter, with internal jugular vein (IJV) cross-sectional area (CSA) variation along the cardiac beat acquired using ultrasound. The resultant CVP and IJV-CSA signals were synchronized with electrocardiogram (ECG) signals acquired from the patients. Autocorrelation signals were derived from the IJV-CSA signals using algorithms in R (open-source statistical software). The correlation r-values for successive lag intervals were extracted and used to build a linear regression model in which mean-CVP was the response variable and the lagging autocorrelation r-values and mean IJV-CSA, were the predictor variables. The optimum model was identified using the minimum AIC value and validated using 10-fold cross-validation. While the CVP and IJV-CSA signals were poorly correlated (mean r = -0.018, SD = 0.357) due to the IJV-CSA signal lagging behind the CVP signal, their autocorrelation counterparts were highly positively correlated (mean r = 0.725, SD = 0.215). Using the lagging autocorrelation r-values as predictors, mean-CVP was predicted with reasonable accuracy (r2 = 0.612), with a mean-absolute-error of 1.455 cmH2O, which rose to 2.436 cmH2O when cross-validation was performed. Mean-CVP can be estimated non-invasively by using the lagged autocorrelation r-values of the IJV-CSA signal. This new methodology may have considerable potential as a clinical monitoring and diagnostic tool.Keywords
Funding Information
- Ministero della Salute (RF-2013-02358029)
This publication has 32 references indexed in Scilit:
- Prospective Comparison of Noninvasive, Bedside Ultrasound Methods for Assessing Central Venous PressureUltraschall in der Medizin - European Journal of Ultrasound, 2012
- Does thoracic pump influence the cerebral venous return?Journal of Applied Physiology, 2012
- Correlation of Internal Jugular Vein/Common Carotid Artery Ratio to Central Venous PressureJournal of Burn Care & Research, 2012
- Diagnostic accuracy of a simple ultrasound measurement to estimate central venous pressure in spontaneously breathing, critically ill patientsJournal of Hospital Medicine, 2009
- Error in Central Venous Pressure MeasurementAnesthesia & Analgesia, 2009
- Clinical epidemiology of heart failureHeart, 2007
- A Comparison by Medicine Residents of Physical Examination Versus Hand-Carried Ultrasound for Estimation of Right Atrial PressureThe American Journal of Cardiology, 2007
- Central venous pressure: A useful but not so simple measurementCritical Care Medicine, 2006
- A new noninvasive method to determine central venous pressureResuscitation, 2006
- Estimation of central venous pressure by ultrasound of the internal jugular veinThe American Journal of Emergency Medicine, 2000