Fault diagnosis method based on multi‐source information fusion for weak interturn short circuit in synchronous condensers
Open Access
- 24 May 2021
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 15 (9) , 1245-1260
Abstract
The interturn short circuit fault in rotor windings is a common fault in a synchronous condenser. Aiming at the early faults that are difficult to detect, the theory of multi‐source information fusion is applied herein for the identification of short circuit faults in the rotor windings of a synchronous condenser. Firstly, a field‐circuit‐network coupling model of a synchronous condenser for high‐voltage direct current (HVDC) transmission was constructed using SIMULINK/ANSYS. The air gap magnetic flux density of the interturn short circuit regulator with a rotor winding was obtained, via co‐simulation, before and after the commutation failure in the HVDC inverter. Further, three‐dimensional models of the stator and rotor of the synchronous condenser were established using ANSYS/Workbench; the stator and rotor vibration responses of the synchronous condenser were monitored before and after the system commutation failure. Secondly, three types of evidence bodies were obtained based on the Dempster–Shafer evidence theory. The results show that the confidence level of the evidence body of each faulted component of the synchronous condenser increases, and the accuracy of fault recognition also increases upon system commutation failure. Finally, a three‐pair‐pole synchronous motor (MJF‐30‐6) was used to simulate the rated and overexcited operations of the synchronous condenser for experimental verification of the feasibility of the proposed method. This method provides a reference for the identification of weak interturn short circuit faults in synchronous condensers.Keywords
Funding Information
- National Natural Science Foundation of China (51777075)
This publication has 15 references indexed in Scilit:
- Vibration characteristic analysis of rotor in excitation winding inter‐turn short circuit state of turbo generatorIEEJ Transactions on Electrical and Electronic Engineering, 2019
- Rotor Interturn Short Circuit Impact on Large Hydrogenerator Magnetic QuantitiesIEEE Transactions on Industry Applications, 2018
- A New Detection Coil Capable of Performing Online Diagnosis of Excitation Winding Short-Circuits in Steam-Turbine GeneratorsIEEE Transactions on Energy Conversion, 2017
- Magnetic AC Impedance Analysis Method Using High-Tc SQUID Based Magnetic Measurement SystemIEEE Transactions on Applied Superconductivity, 2016
- Diagnosis of Short Circuit Faults Within Turbogenerator Excitation Winding Based on the Expected Electromotive Force MethodIEEE Transactions on Energy Conversion, 2016
- Non-Invasive Detection of Rotor Short-Circuit Fault in Synchronous Machines by Analysis of Stray Magnetic Field and Frame VibrationsIEEE Transactions on Magnetics, 2016
- Direct-Current Predictive Control Strategy for Inhibiting Commutation Failure in HVDC ConverterIEEE Transactions on Power Systems, 2014
- Effect of a SFCL on Commutation Failure in a HVDC SystemIEEE Transactions on Applied Superconductivity, 2012
- Fault diagnosis of machines based on D–S evidence theory. Part 1: D–S evidence theory and its improvementPattern Recognition Letters, 2006
- Investigation of the use of inverter control strategy instead of synchronous condensers at inverter terminal of an HVDC systemIEEE Transactions on Power Delivery, 2000