Prophylaxis of Restenosis With 186 Re-Labeled Stents in a Rabbit Model
- 24 July 2001
- journal article
- other
- Published by Wolters Kluwer Health in Circulation
- Vol. 104 (4) , 480-485
Abstract
Background Intraluminal β-irradiation has been shown to decrease neointimal proliferation after angioplasty in experimental models. The purpose of this study was to test the technical feasibility and biological effects of 186 Re-labeled stents. Methods and Results Thirty-four New Zealand White rabbits were fed a 0.5% cholesterol diet before balloon angioplasty and insertion of Palmaz stents in the infrarenal aorta. The animals were killed 7 weeks after stent implantation. Two of 34 animals died prematurely (aortic leak, pneumonia). Control stents (n=7) were compared with 186 Re stents (2.6 MBq [n=6], 8.1 MBq [n=5], 16.0 MBq [n=6], and 25.3 MBq [n=8]). Stent application was successful in all cases. No thrombus occlusion was observed. After 7 weeks, neointima formation was 2.2±0.2 mm 2 in the control group. In the treatment groups, a dose-dependent neointima reduction was detectable (0.5±0.5 mm 2 [2.6 MBq], 0.4±0.4 mm 2 [8.1 MBq], and 0 mm 2 [16.0 MBq, 25.3 MBq]). No induction of neointimal formation was observed at the edges of the stents. Radiation resulted in delayed reendothelialization. Conclusions 186 Re stents were capable of reducing neointima formation in a dose-dependent fashion. 186 Re stents did not cause late thrombosis or neointimal induction at the stent margins in the observation period of 7 weeks.Keywords
This publication has 14 references indexed in Scilit:
- Edge Restenosis After Implantation of High Activity 32 P Radioactive β-Emitting StentsCirculation, 2000
- Intracoronary γ-Radiation Therapy After Angioplasty Inhibits Recurrence in Patients With In-Stent RestenosisCirculation, 2000
- Prevention of Coronary RestenosisCirculation, 2000
- Intracoronary β-Radiation Therapy Inhibits Recurrence of In-Stent RestenosisCirculation, 2000
- Three-Year Clinical and Angiographic Follow-Up After Intracoronary RadiationCirculation, 2000
- Long-Term Coronary Vascular Response to 32 P β-Particle–Emitting Stents in a Canine ModelCirculation, 1999
- Effects of Endovascular Radiation From a β-Particle–Emitting Stent in a Porcine Coronary Restenosis ModelCirculation, 1996
- Pure β-ParticleEmitting Stents Inhibit Neointima Formation in RabbitsCirculation, 1996
- Inhibition of Neointimal Proliferation With Low-Dose Irradiation From a β-Particle–Emitting StentCirculation, 1996
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992