Measurement and correction of misalignments in corneal topography using the null-screen method
Open Access
- 14 January 2021
- journal article
- research article
- Published by Optica Publishing Group in OSA Continuum
- Vol. 4 (1) , 158-170
Abstract
Misalignments are a common problem in corneal topography reconstruction. To determine the topography of the surface using a corneal topographer based on the null-screen method, it is necessary to measure errors caused by mechanical misalignment of the topographer, which could influence the results of this technique but are not related to the quality of the corneal surface. To evaluate the variability in measurements, in this work, we simulate some misalignments in the optical system, for the simulation we design a semi-radial null-screen to test a reference spherical surface to identify the variations in results introduced by misalignment errors of the corneal topographer with respect to the test surface. According to the simulations, the accuracy of the null-screen method ranges from 0.81 µm to 2.84 µm for typical tilt, decentering, and defocusing errors. Experimental results for the testing of a spherical surface are shown. After removing the misalignments, we found that the variations are approximately 3.5 μm rms value measured with respect to the best-fitting sphere, and the radius of curvature differs approximately 0.06% from the design value.Keywords
Funding Information
- Secretaría de Ciencia, Humanidades, Tecnología e Innovación (293411)
- Dirección General de Asuntos del Personal Académico, Universidad Nacional Autónoma de México (PE101120, TA100319, TA100519)
This publication has 12 references indexed in Scilit:
- Fast conical surfaces evaluation with null-screens and randomized algorithmsApplied Optics, 2017
- Surface shape evaluation with a corneal topographer based on a conical null-screen with a novel radial point distributionApplied Optics, 2015
- Optical Devices in Ophthalmology and Optometry2014
- Lens distortion models evaluationApplied Optics, 2010
- Quantitative evaluation of an off-axis parabolic mirror by using a tilted null screenApplied Optics, 2009
- Testing fast aspheric concave surfaces with a cylindrical null screenApplied Optics, 2008
- Measurement of moments for centroid estimation in Shack–Hartmann wavefront sensor—a wavelet-based approach and comparison with other methodsOptik, 2005
- The Accuracy and Precision Performance of Four Videokeratoscopes in Measuring Test SurfacesOptometry and Vision Science, 2000
- Null-screen testing of fast convex aspheric surfacesApplied Optics, 2000
- Misalignment effects of the Shack–Hartmann sensorApplied Optics, 1998