Novel Diagnostic Algorithm for the Floating and Sunken Pulse Qualities and Its Clinical Test
Authors:
Open Access
- 1 January 2011
- journal article
- research article
- Published by Wiley in Evidence-Based Complementary and Alternative Medicine
- Vol. 2011 (1) , 813427
Abstract
We propose a novel classification algorithm for the floating pulse and the sunken pulse using a newly defined coefficient (Cfs). To examine the validity of the proposed algorithm, we carried out a clinical test in which 12 oriental medical doctors made pairwise diagnoses on the pulses of volunteering subjects. 169 subjects were simultaneously diagnosed by paired doctors, and the diagnoses in 121 subjects were concordant, yielding an accuracy of 72% and a Matthews correlation coefficient of 0.42, which indicates reasonable agreement between doctors. Two sampleT‐tests showed that subjects in the sunken pulse group had significantly higher BMI andCfs(P< .05) than those in the floating pulse group. The pulse classification by the algorithm converged with the diagnoses of paired doctors with an accuracy up to 69%. With these results, we confirm the validity of the novel classification algorithm for the floating and sunken pulses.Keywords
Funding Information
- Korea Institute of Oriental Medicine (K10070, 10028438)
- Ministry of Knowledge Economy (K10070, 10028438)
This publication has 10 references indexed in Scilit:
- Developing the Effective Method of Spectral Harmonic Energy Ratio to Analyze the Arterial Pulse SpectrumEvidence-Based Complementary and Alternative Medicine, 2011
- A Clinical Study of the Pulse Wave Characteristics at the Three Pulse Diagnosis Positions of Chon, Gwan and CheokEvidence-Based Complementary and Alternative Medicine, 2011
- Radial Pressure Pulse and Heart Rate Variability in Heat‐ and Cold‐Stressed HumansEvidence-Based Complementary and Alternative Medicine, 2010
- Classification of Pulse Waveforms Using Edit Distance with Real PenaltyEURASIP Journal on Advances in Signal Processing, 2010
- Wrist pulse signal diagnosis using modified Gaussian models and Fuzzy C-Means classificationMedical Engineering & Physics, 2009
- A Study on Correlation between BMI and Oriental Medical Pulse Diagnosis Using Ultrasonic Wave2009
- Variations in non-invasive radial artery pulse waveform at different measuring positions2008
- A study on characteristics of radial arteries through ultrasonic waves2008
- Functional Somatic Syndromes: Emerging Biomedical Models and Traditional Chinese MedicineEvidence-Based Complementary and Alternative Medicine, 2000
- Variation Analysis of Sphygmogram to Assess Cardiovascular System under MeditationEvidence-Based Complementary and Alternative Medicine, 2000