Feasibility of Harmonic Motion Imaging Using a Single Transducer: In Vivo Imaging of Breast Cancer in a Mouse Model and Human Subjects
- 30 April 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (5) , 1390-1404
Abstract
Harmonic motion imaging (HMI) interrogates the mechanical properties of tissues by simultaneously generating and tracking harmonic oscillation using focused ultrasound and imaging transducers, respectively. Instead of using two transducers, the objective of this work is to develop a single transducer HMI (ST-HMI) to both generate and track harmonic motion at “on-axis” to the force for facilitating data acquisition. In ST-HMI, the amplitude-modulated force was generated by modulating excitation pulse duration and tracking of motion was performed by transmitting tracking pulses interleaved between excitation pulses. The feasibility of ST-HMI was performed by imaging two elastic phantoms with three inclusions (N = 6) and comparing it with acoustic radiation force impulse (ARFI) imaging, in vivo longitudinal monitoring of 4T1, orthotropic breast cancer mice (N = 4), and patients (N = 3) with breast masses in vivo. Six inclusions with Young's moduli of 8, 10, 15, 20, 40, and 60 kPa were embedded in a 5 kPa background. The ST-HMI-derived peak-to-peak displacement (P2PD) successfully detected all inclusions with R 2 =0.93 of the linear regression between the P2PD ratio of background to inclusion versus Young's moduli ratio of inclusion to background. The contrasts of 10 and 15 kPa inclusions were higher in ST-HMI than ARFI-derived images. In the mouse study, the median P2PD ratio of tumor to non-cancerous tissues was 3.0, 5.1, 6.1, and 7.7 at 1, 2, 3, and 4 weeks post-injection of the tumor cells, respectively. In the clinical study, ST-HMI detected breast masses including fibroadenoma, pseudo angiomatous stromal hyperplasia, and invasive ductal carcinoma with a P2PD ratio of 1.37, 1.61, and 1.78, respectively. These results indicate that ST-HMI can assess the mechanical properties of tissues via generation and tracking of harmonic motion “on-axis” to the ARF. This study is the first step towards translating ST-HMI in clinics.Keywords
Funding Information
- NIH (R01 CA228275)
This publication has 67 references indexed in Scilit:
- Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave ElastographyRadiology, 2015
- Optical coherence elastography for tissue characterization: a reviewJournal of Biophotonics, 2014
- Ultrasound Elastography: The New Frontier in Direct Measurement of Muscle StiffnessArchives of Physical Medicine and Rehabilitation, 2014
- Dynamic Simulation of Viscoelastic Soft Tissue in Acoustic Radiation Force Creep ImagingJournal of Biomechanical Engineering, 2014
- Shear wave elastography of tumour growth in a human breast cancer model with pathological correlationEuropean Radiology, 2013
- Assessment of Liver Viscoelasticity by Using Shear Waves Induced by Ultrasound Radiation ForceRadiology, 2013
- US Renal Data System 2011 Annual Data ReportAmerican Journal of Kidney Diseases, 2012
- Quantitative viscoelastic parameters measured by harmonic motion imagingPhysics in Medicine & Biology, 2009
- Analysis of contrast in images generated with transient acoustic radiation forceUltrasound in Medicine & Biology, 2006
- Localized harmonic motion imaging: theory, simulations and experimentsUltrasound in Medicine & Biology, 2003