The effect of adjustable suture (Khaw) trabeculectomy on intraocular pressure: a retrospective case series
Authors:
Open Access
- 23 May 2015
- journal article
- Published by Springer Nature in International Ophthalmology
- Vol. 36 (1) , 97-104
Abstract
The aim of the study is to investigate long-term intraocular pressure (IOP) outcome as well as complications associated with adjustable suture trabeculectomy in glaucoma patients who were uncontrolled under maximum medical therapy. In this retrospective case series, 35 eyes of 30 patients are included in the study. Adjustable suture trabeculectomy with 0.2 mg/cc mitomycin-C for 3 min was performed by the same surgeon. Subconjunctival 5-fluorouracil injection, transconjunctival suture adjustment, digital massage, and/or argon suturolysis were utilized postoperatively as needed. Complete success, qualified success, and failure were defined as IOP ≤18 mmHg without medication, IOP ≤18 mmHg with one or more medications, and IOP >18 mmHg with medication or need for additional glaucoma surgery, respectively. Of the 35 eyes, 13 had primary open angle, 18 had psuedoexfoliative, 1 had juvenile, 1 had pigmentary, 1 had uveitic, and 1 had chronic angle-closure glaucoma. Mean preoperative IOP of 30.1 ± 10.5 mmHg dropped to 10.8 ± 4.7 mmHg (p < 0.001) after a mean follow-up of 595 ± 435 days. Nine eyes had the desired IOP on first postoperative day where no transconjunctival suture adjustment was performed. Remaining 26 eyes required a mean of two adjustments (range 1–7) during the first postoperative 24 days in order to achieve a desirable IOP. Complete success, qualified success, and failure were observed in 28 (80 %), 5 (14 %), and 2 (6 %) eyes, respectively. There were no serious complications related to adjustable suture trabeculectomy. We believe adjustable suture trabeculectomy to be a safe and effective alternative to standard trabeculectomy where a desirable low IOP can be achieved.Keywords
This publication has 15 references indexed in Scilit:
- A Comparison of the Intraocular Pressure Lowering Effect of Adjustable Suture Versus Laser Suture Lysis for TrabeculectomyJournal of Glaucoma, 2011
- Releasable Suture TechniqueJournal of Glaucoma, 2008
- Laser Suture Lysis or Releasable Sutures After TrabeculectomyJournal of Glaucoma, 2007
- Efficacy and Complications of Releasable Suture Trabeculectomy and Standard TrabeculectomyInternational Ophthalmology, 2006
- Safe trabeculectomy technique: long term outcomeBritish Journal of Ophthalmology, 2006
- Trabeculectomy With Releasable SuturesArchives of Ophthalmology (1950), 1998
- Number of people with glaucoma worldwide.British Journal of Ophthalmology, 1996
- The predictive value of post-operative intraocular pressures following trabeculectomyEye, 1994
- Trabeculectomy With Releasable SuturesArchives of Ophthalmology (1950), 1994
- The Ocular Histopathologic Effect of Krypton and Argon Laser RadiationAmerican Journal of Ophthalmology, 1969