Effect of Hypertension on the Closing Dynamics and Lagrangian Blood Damage Index Measure of the B-Datum Regurgitant Jet in a Bileaflet Mechanical Heart Valve
- 23 August 2013
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (1) , 110-122
Abstract
We hypothesize that the formation of the closing vortex and subsequent b-datum regurgitation jet in bileaflet mechanical heart valves is governed by the magnitude of the driving mean aortic pressure (MAP), and that this sensitivity does impact the blood damage index (BDI) corresponding to platelet activation and lysis. High spatial resolution time resolved (1 kHz) as well as phase locked particle image velocimetry techniques captured the dynamic leaflet closure and regurgitation jet of a model 25 mm St. Jude Medical BMHV. Cell trajectories were estimated using Lagrangian particle tracking analysis while the leaflet kinematics was quantified by tracking the leaflet tip-position throughout closure. The non-principal as well as principal shear stress loading histories along each cell trajectory revealed BDI for platelet activation and lysis as a function of cell initial position, release time-point, and blood pressure. Results show that the leaflet closing time reduces by roughly 10 ms, in response to an increase in MAP by 40 mmHg. We report that higher MAP leads to a stronger b-datum vortex and jet formation. Platelet activation BDI lowers with a higher MAP due to reduction in exposure times despite an increase in principal shear stress experienced. Platelet lysis BDI however increases with higher MAP. Maximum BDI may occur for cells initially in the b-datum zone during the onset of leaflet closure. Our results provide a better understanding of BDI of the regurgitant b-datum jet and sheds light on the potential importance of blood damage testing under hypertensive conditions.Keywords
This publication has 28 references indexed in Scilit:
- Aortic Root Compliance Influences Hemolysis in Mechanical Heart Valve Prostheses: An In-Vitro StudyThe International Journal of Artificial Organs, 2012
- Near Valve Flows and Potential Blood Damage During Closure of a Bileaflet Mechanical Heart ValveJournal of Biomechanical Engineering, 2011
- High-Resolution Measurement of the Unsteady Velocity Field to Evaluate Blood Damage Induced by a Mechanical Heart ValveAnnals of Biomedical Engineering, 2011
- Dynamic Hemodynamic Energy Loss in Normal and Stenosed Aortic ValvesJournal of Biomechanical Engineering, 2010
- FLUID MECHANICS OF ARTIFICIAL HEART VALVESClinical and Experimental Pharmacology and Physiology, 2009
- A Detailed Fluid Mechanics Study of Tilting Disk Mechanical Heart Valve Closure and the Implications to Blood DamageJournal of Biomechanical Engineering, 2008
- Platelet Activation Due to Hemodynamic Shear Stresses: Damage Accumulation Model and Comparison to In Vitro MeasurementsASAIO Journal, 2008
- Fluid Dynamic Assessment of Three Polymeric Heart Valves Using Particle Image VelocimetryAnnals of Biomedical Engineering, 2006
- The Power‐law Mathematical Model for Blood Damage Prediction: Analytical Developments and Physical InconsistenciesArtificial Organs, 2004
- Relative Blood Damage in the Three Phases of a Prosthetic Heart Valve Flow CycleASAIO Journal, 1993