An optimized lead system for long-term esophageal electrocardiography
Authors:
- A HaeberlinAHA Haeberlin
- T MarisaTMT Marisa
- D MattleDMD Mattle
- R AbächerliRAR Abächerli
- J GoetteJGJ Goette
- M JacometMJM Jacomet
- R VogelRVR Vogel
- 27 February 2014
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 35 (4) , 517-532
Abstract
Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ECG might overcome these limitations but requires a dedicated lead system and recorder design. To this end, we analysed multiple-lead esophageal ECGs with respect to signal quality by describing the ECG waves as a function of the insertion level, interelectrode distance, electrode shape and amplifier's input range. The results derived from clinical data show that two bipolar esophageal leads, an atrial lead with short (15 mm) interelectrode distance and a ventricular lead with long (80 mm) interelectrode distance provide non-inferior ventricular signal strength and superior atrial signal strength compared to standard surface lead II. High atrial signal slope in particular is observed with the atrial esophageal lead. The proposed esophageal lead system in combination with an increased recorder input range of ±20 mV minimizes signal loss due to excessive electrode motion typically observed in esophageal ECGs. The design proposal might help to standardize long-term esophageal ECG registrations and facilitate novel ECG classification systems based on the independent detection of ventricular and atrial electrical activity.Keywords
This publication has 36 references indexed in Scilit:
- Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposesMedical Engineering & Physics, 2013
- The optimal lead insertion depth for esophageal ECG recordings with respect to atrial signal qualityJournal of Electrocardiology, 2013
- A new method of filtering T waves to detect hidden P waves in electrocardiogram signalsEP Europace, 2011
- Excessive Supraventricular Ectopic Activity and Increased Risk of Atrial Fibrillation and StrokeCirculation, 2010
- Eigenleads: ECG Leads for Maximizing Information Capture and Improving SNRIEEE Transactions on Information Technology in Biomedicine, 2009
- Comparison of the Amplitude of the P-Wave from Intracardiac Electrocardiogram Obtained by Means of a Central Venous Catheter Filled With Saline Solution to That Obtained Via Esophageal ElectrocardiogramThe American Journal of Cardiology, 2006
- Comparing stress ECG enhancement algorithmsIEEE Engineering in Medicine and Biology Magazine, 1996
- Automated interpretation of cardiac arrhythmiasJournal of Electrocardiology, 1993
- Trans‐Esophageal PacingPacing and Clinical Electrophysiology, 1983
- The Anatomic Relationship of the Esophageal Lead to the Left AtriumPacing and Clinical Electrophysiology, 1982