Predictive factors of discordance between the instantaneous wave‐free ratio and fractional flow reserve
- 31 January 2019
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 94 (3) , 356-363
Abstract
Objectives: To identify clinical, angiographic and hemodynamic predictors of discordance between instantaneous wave‐free ratio (iFR) and fractional flow reserve (FFR).Background: The iFR was found to be non‐inferior to the gold‐standard FFR for guiding coronary revascularization, although it is discordant with FFR in 20% of cases. A better understanding of the causes of discordance may enhance application of these indices.Methods: Both FFR and iFR were measured in the prospective multicenter CONTRAST study. Clinical, angiographic and hemodynamic variables were compared between patients with concordant values of FFR and iFR (cutoff ≤0.80 and ≤0.89, respectively).Results: Out of the 587 patients included, in 466 patients (79.4%) FFR and iFR agreed: both negative, n = 244 (41.6%), or positive, n = 222 (37.8%). Compared with FFR, iFR was negative discordant (FFR+/iFR‐) in 69 (11.8%) patients and positive discordant (FFR‐/iFR+) in 52 (8.9%) patients. On multivariate regression, stenosis location (left main or proximal left anterior descending) (OR: 3.30[1.68;6.47]), more severe stenosis (OR: 1.77[1.35;2.30]), younger age (OR: 0.93[0.90;0.97]), and slower heart rate (OR: 0.59[0.42;0.75]) were predictors of a negative discordant iFR. Absence of a beta‐blocker (OR: 0.41[0.22;0.78]), older age (OR: 1.04[1.00;1.07]), and less severe stenosis (OR: 0.69[0.53;0.89]) were predictors of a positive discordant iFR.Conclusions: During iFR acquisition, stenosis location, stenosis degree, heart rate, age and use of beta blockers influence concordance with FFR and should be taken into account when interpreting iFR.Keywords
Funding Information
- Fédération Française de Cardiologie
- AstraZeneca
- Cardiovascular Research Foundation
- Medtronic
- Boston Scientific Corporation
- Abbott Vascular (NCT02184117)
This publication has 17 references indexed in Scilit:
- The Influence of Lesion Location on the Diagnostic Accuracy of Adenosine-Free Coronary Pressure Wire MeasurementsJACC: Cardiovascular Interventions, 2016
- Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve AssessmentJACC: Cardiovascular Interventions, 2016
- Quantification of the Effect of Pressure Wire Drift on the Diagnostic Performance of Fractional Flow Reserve, Instantaneous Wave-Free Ratio, and Whole-Cycle Pd/PaCirculation: Cardiovascular Interventions, 2016
- Deferral vs. performance of percutaneous coronary intervention of functionally non-significant coronary stenosis: 15-year follow-up of the DEFER trialEuropean Heart Journal, 2015
- The impact of age on fractional flow reserve-guided percutaneous coronary intervention: A FAME (Fractional Flow Reserve versus Angiography for Multivessel Evaluation) trial substudyInternational Journal of Cardiology, 2014
- 2014 ESC/EACTS Guidelines on myocardial revascularizationEuropean Heart Journal, 2014
- Fractional Flow Reserve–Guided PCI versus Medical Therapy in Stable Coronary DiseaseNew England Journal of Medicine, 2012
- The impact of aging and atherosclerotic risk factors on transthoracic coronary flow reserve in subjects with normal coronary angiographyCardiovascular Ultrasound, 2012
- Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary InterventionNew England Journal of Medicine, 2009
- Simultaneous Coronary Pressure and Flow Velocity Measurements in HumansCirculation, 1996