A “2-in-1” Bioanalytical System Based on Nanocomposite Conductive Polymers for Early Detection of Surface Water Pollution
Open Access
Abstract
This work proposes an approach to the formation of receptor elements for the rapid diagnosis of the state of surface waters according to two indicators: the biochemical oxygen demand (BOD) index and toxicity. Associations among microorganisms based on the bacteria P. yeei and yeast S. cerevisiae, as well as associations of the yeasts O. polymorpha and B. adeninivorans, were formed to evaluate these indicators, respectively. The use of nanocomposite electrically conductive materials based on carbon nanotubes, biocompatible natural polymers—chitosan and bovine serum albumin cross-linked with ferrocenecarboxaldehyde, neutral red, safranin, and phenosafranin—has made it possible to expand the analytical capabilities of receptor systems. Redox polymers were studied by IR spectroscopy and Raman spectroscopy, the contents of electroactive components were determined by atomic absorption spectroscopy, and electrochemical properties were studied by electrochemical impedance and cyclic voltammetry methods. Based on the proposed kinetic approach to modeling individual stages of bioelectrochemical processes, the chitosan–neutral red/CNT composite was chosen to immobilize the yeast association between O. polymorpha (ks = 370 ± 20 L/g × s) and B. adeninivorans (320 ± 30 L/g × s), and a bovine serum albumin (BSA)–neutral composite was chosen to immobilize the association between the yeast S. cerevisiae (ks = 130 ± 10 L/g × s) and the bacteria P. yeei red/CNT (170 ± 30 L/g × s). After optimizing the composition of the receptor systems, it was shown that the use of nanocomposite materials together with associations among microorganisms makes it possible to determine BOD with high sensitivity (with a lower limit of 0.6 mg/dm3) and detect the presence of a wide range of toxicants of both organic and inorganic origin. Both receptor elements were tested on water samples, showing a high correlation between the results of biosensor analysis of BOD and toxicity and the results of standard analytical methods. The results obtained show broad prospects for creating sensitive and portable bioelectrochemical sensors for the early warning of environmentally hazardous situations based on associations among microorganisms and nanocomposite materials.Keywords
Funding Information
- Russian Science Foundation (23-73-01220, DS/101/BASiB/23/TO)
- Government of the Tula Region (23-73-01220, DS/101/BASiB/23/TO)
This publication has 50 references indexed in Scilit:
- South Africa’s Water Predicament2023
- Polyphenazine and polytriphenylmethane redox polymer/nanomaterial–based electrochemical sensors and biosensors: a reviewMicrochimica Acta, 2021
- A kinetic approach to the formation of two-mediator systems for developing microbial biosensors as exemplified by a rapid biochemical oxygen demand assay3 Biotech, 2021
- Bacterial Cellulose Immobilized S. cerevisiae as Microbial Sensor for Rapid BOD DetectionFibers and Polymers, 2021
- Redox Mediator‐Based Microbial Biosensors for Acute Water Toxicity Assessment: A Critical ReviewChemElectroChem, 2020
- Registration of BOD using Paracoccus yeei bacteria isolated from activated sludge3 Biotech, 2020
- Development of a mediated whole cell-based electrochemical biosensor for joint toxicity assessment of multi-pollutants using a mixed microbial consortiumAnalytica Chimica Acta, 2016
- A Ferricyanide‐mediated Activated Sludge Bioassay for Determination of the Toxicity of WaterElectroanalysis, 2015
- Yeast-based self-organized hybrid bio-silica sol–gels for the design of biosensorsBiosensors and Bioelectronics, 2015
- A novel catabolic activity of Pseudomonas veronii in biotransformation of pentachlorophenolApplied Microbiology and Biotechnology, 2003