Current integrated technique for insulation diagnosis of water-tree degraded cable
Authors:
- 14 March 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 25 (1) , 94-101
Abstract
The diagnosis of insulation performance in the high-voltage alternating current (HVAC) and high-voltage direct current (HVDC) systems has always attracted many researchers in the field of electrical engineering. New diagnostic technology and condition monitoring apparatus are of prime importance for HVAC and HVDC developments. In this study, we introduce a valuable technique called direct current integrated charge (DCIC-Q(t)) for determining the degradation of insulating materials by means of charge accumulation. This work demonstrates the typical results of full-size cross-linked polyethylene (XLPE) cables by using this effective method. Firstly, we describe the basic measurement principle of DCIC-Q(t) technique and the evaluation details of the degradation. Then, the validity of this technique is confirmed by comparing with the pulsed electroacoustic (PEA) results. The similar charge behaviors of polystyrene and low-density polyethylene are presented via the DCIC-Q(t) and PEA methods, which indicates the good availability of this technique. Three underground, full-size, 6.6-kV XLPE cables were diagnosed using the DCIC-Q(t) method. Two cables were degraded by water and electric stress for a different time under controlled conditions. The degradation extent can be evaluated easily by the charge accumulation from the DCIC-Q(t) results. Furthermore, based on the results of charge dynamics related to the applied voltage, the properties of the degraded cable by water tree are discussed.Keywords
This publication has 11 references indexed in Scilit:
- New diagnostic method of electrical insulation properties based on current integrationIEEE Transactions on Dielectrics and Electrical Insulation, 2017
- HVDC insulation and diagnosticsIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Stress conditions in HVDC equipment and routes to in service failureIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Measuring a possible HVDC insulation killer: fast charge pulsesIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oilIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Shed parameters optimization of composite post insulators for UHV DC flashover voltages at high altitudesIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Charge transport modeling in insulating polymers: from molecular to macroscopic scaleIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- Space charge phenomenology in polymeric insulating materialsIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- Estimation of conductivity and permittivity of water trees in PE from space charge distribution measurementsIEEE Transactions on Dielectrics and Electrical Insulation, 2001
- Direct observation of time-dependent space charge profiles in XLPE cable under high electric fieldsIEEE Transactions on Dielectrics and Electrical Insulation, 1994