Abstract
In this study, we have developed the technique of electrostatic manipulation of a dielectric microparticle by a single probe. The manipulation system consists of three objects: a conductive probe as a manipulating tool, a conductive plate as a substrate, and a dielectric particle that dubs as a microparticle. In manipulating 60 μm in diameter particles of polystyrene, when a constant probe-substrate voltage was applied, we observed the phenomenon of the particle repeatedly moving up and down between the substrate and the probe tip, similarly to a “micro-dribble.” In order to understand the mechanism of the phenomenon, we have proposed a model with a resistor-capacitor circuit in consideration of the surface conductivity of the dielectric particle such that the model can explain the micro-dribble phenomenon in terms of the time constant of the circuit. By a single-pulse voltage the duration of which was designed (selected) on the basis of the frequency of the observed micro-dribble, we experimentally demonstrated the electrostatic micromanipulation by picking up/placing the polystyrene particle using the single probe. Although the success rate of 42% requires further improvement, the experimental result indicates the feasibility of the technique, which can be applied to future technology for microdevice packaging or assembly.

This publication has 8 references indexed in Scilit: