Abstract
Methods: From 1992 to 2008, 2,415 patients receiving an ICD at the Leiden University Medical Center were analyzed. Pocket-related complications requiring surgical re-intervention following ICD implantation or replacement were noted. Elective device replacement, lead failure, and device malfunction were not considered pocket-related complications. Results: A total of 3,161 ICDs were included in the analysis. In total, 145 surgical re-interventions were required in 122 (3.9%) ICDs implanted in 114 (4.7%) unique patients. Three-year cumulative incidence for first surgical re-intervention in all ICDs was 4.7% (95% confidence interval [CI] 3.9-5.5%). Replacement ICDs exhibited a doubled requirement for surgical re-intervention (rate ratio 2.2, 95% CI 1.5-3.0). Compared to first implanted ICDs, the occurrence of surgical re-intervention in replacements was 2.5 (95% CI 1.6-3.7) times higher for infectious and 1.7 (95% CI 0.9-3.0) for noninfectious causes. Subdivision by the number of ICD replacements showed an increase in the annual risk for surgical re-intervention, ranging from 1.5% (95% CI 1.2-1.9%) for the first, to 8.1% (95% CI 1.7-18.3%) for the fourth implanted ICD. Conclusions: ICD replacement is associated with a doubled risk for pocket-related surgical re-interventions. Furthermore, the need for re-intervention increases with every consecutive replacement. (PACE 2010; 1013-1019).Keywords
This publication has 27 references indexed in Scilit:
- Clinical implementation of guidelines for cardioverter defibrillator implantation: lost in translation?Netherlands Heart Journal, 2007
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureNew England Journal of Medicine, 2005
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- Randomized Comparison of Antiarrhythmic Drug Therapy With Implantable Defibrillators in Patients Resuscitated From Cardiac ArrestCirculation, 2000
- Canadian Implantable Defibrillator Study (CIDS)Circulation, 2000
- A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1999
- Late complications following permanent pacemaker implantation or elective unit replacementHeart, 1998
- Role of the Preaxillary Flora in Pacemaker InfectionsCirculation, 1998
- A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular ArrhythmiasNew England Journal of Medicine, 1997
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaNew England Journal of Medicine, 1996