Comparison of analytical performance and biological variability of three bone resorption assays
Authors:
- Hsin-Shan J JuHJHsin-Shan J Ju
- Sunny LeungSLSunny Leung
- Christy ScherrerCSChristy Scherrer
- Karen ShepardKSKaren Shepard
- Dean JenkinsDJDean Jenkins
- Jane KnudsenJKJane Knudsen
- Robert CannonRCRobert Cannon
Open Access
- 1 September 1997
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (9) , 1570-1576
Abstract
We have compared the analytical performance and biological variability of three commercially available bone resorption assays: Pyrilinks®-D, Osteomark®, and CrossLaps™, for the measurement of urinary free deoxypyridinoline (Dpd), cross-linked N-telopeptides of type I collagen (NTx), and linear C-telopeptides of type I collagen (CTx), respectively. The intraassay and interassay CVs for precision of the Dpd and NTx assays were <10% for analyte concentrations greater than the second calibrator (i.e., 3 nmol/L Dpd or 30 nmol bone collagen equivalents/L NTx). The CTx assay demonstrated poor precision for analyte concentration lower than the third calibrator (i.e., 200 μg/L). The NTx assay exhibited nonlinear recovery for sample dilutions prepared in buffer; however, this nonlinear recovery could be corrected for sample dilutions made in urine at a low analyte concentration. Supplement recoveries of each of the three assays were within 100% ± 10% on average. All three analytes showed stability through five freeze–thaw cycles. The mean day-to-day variations were 16% for Dpd, and 23% for both NTx and CTx. Similar diurnal rhythm was observed for all three assays on average, with the peak in the early morning and the nadir in the afternoon. Mean amplitude of the diurnal variation was 37% for Dpd and NTx, and 57% for CTx. Variations within the reference intervals for a healthy premenopausal population were 28% for Dpd, 57% for NTx, and 56% for CTx. Pyrilinks-D has demonstrated analytical precision and accuracy equal or superior to Osteomark and CrossLaps in all areas. Dpd exhibits the least biological variability day-to-day, within individuals across the diurnal cycle, and within a healthy premenopausal population.Keywords
This publication has 31 references indexed in Scilit:
- Biochemical Markers of Bone Resorption Compared with Estimates of Bone Resorption from Radiotracer Kinetic Studies in OsteoporosisJournal of Bone and Mineral Research, 1997
- ASBMR 18th Annual MeetingJournal of Bone and Mineral Research, 1996
- Automatic-interactive measurement of resorption cavities in transiliac bone biopsies and correlation with deoxypyridinolineBone, 1995
- Factors affecting the assay of urinary 3–hydroxy pyridiniurn crosslinks of collagen as markers of bone resorptionEuropean Journal of Clinical Investigation, 1993
- PHYSIOLOGICAL VARIATIONS IN THE URINARY EXCRETION OF PYRIDINIUM CROSSLINKS OF COLLAGENRheumatology, 1993
- Urinary pyridinium crosslinks of collagen Specific markers of bone resorption in metabolic bone diseaseTrends in Endocrinology & Metabolism, 1992
- Evaluation of urinary hydroxypyridinium crosslink measurements as resorption markers in metabolic bone diseasesEuropean Journal of Clinical Investigation, 1991
- Matrix proteins of the skeletonCurrent Opinion in Cell Biology, 1990
- Urinary excretion of pyridinium crosslinks: a new marker of bone resorption in metabolic bone diseaseBone and Mineral, 1990
- Pyridinium crosslinks of bone collagen and their location in peptides isolated from rat femurBiochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology, 1987