Technical note: Comparison between two tracing methods with ultrasonography to determine lumen area of the caudal artery in beef cattle1
- 1 January 2009
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Animal Science
- Vol. 87 (1) , 371-374
Abstract
Two experiments were conducted to compare variation between 2 tracing methods in measuring cross-sectional lumen area of the caudal artery in 5 beef heifers on 3 different dates (Exp. 1) and to compare tracing methods in detecting changes in artery lumen area after 5 heifers were switched from a diet containing nonendophyte-infected tall fescue [Schedonorus arundinaceus (Schreb.) Dumort] seed to one containing endophyte-infected tall fescue seed (Exp. 2). Lumen area determined by tracing the Doppler flow signal was 25% less than that determined by tracing the intima of the connective tissue, but there was no difference (P = 0.90) in the variation of measures between the 2 methods in Exp. 1. Declines in lumen area were detected at the same level of significance (P < 0.01) for both tracing methods after cattle in Exp. 2 were switched from noninfected to infected tall fescue diets. Variation in lumen areas was different between noninfected and infected diets with tracing the Doppler flow signal (P < 0.05) or the intima of the connective tissue (P < 0.01). Results indicated that lumen area of the caudal artery can be measured with similar precision by tracing the intima of the connective tissue in the artery wall or the outer boundary of the Doppler flow signal. Copyright © 2009. . Copyright 2009 Journal of Animal ScienceKeywords
This publication has 10 references indexed in Scilit:
- Ergovaline-induced vasoconstriction in an isolated bovine lateral saphenous vein bioassay1Journal of Animal Science, 2007
- Hemodynamic responses of the caudal artery to toxic tall fescue in beef heifers1Journal of Animal Science, 2007
- Spectral waveform analysis of major arteries in conscious dogs by Doppler ultrasonographyVeterinary Radiology & Ultrasound, 2004
- Simultaneous assessment of diameter and pressure waveforms in the carotid arteryUltrasound in Medicine & Biology, 2004
- Variability of Doppler ultrasound measurements of hindlimb blood flow in conscious horsesEquine Veterinary Journal, 2000
- PULSED WAVE‐DOPPLER ULTRASONOGRAPHIC EVALUATION OF THE COMMON CAROTID ARTERY IN THE RESTING HORSE: PHYSIOLOGIC DATAVeterinary Radiology & Ultrasound, 1997
- Indexes of Flow and Cross-sectional Area of the Middle Cerebral Artery Using Doppler Ultrasound During Hypoxia and Hypercapnia in HumansStroke, 1996
- Use of pulsed-wave Doppler echocardiography to determine aortic and pulmonary velocity and flow variables in clinically normal dogsAmerican Journal of Veterinary Research, 1991
- Analysis of ergopeptine alkaloids in endophyte-infected tall fescueJournal of Agricultural and Food Chemistry, 1988
- Factors that Influence the Value of the Coefficient of Determination in Simple Linear and Nonlinear Regression ModelsPhytopathology®, 1987