Abstract
The operating conditions can have uncontrolled effects on the voltage of a High-Temperature Proton Exchange Membrane Fuel Cell (HT-PEMFC). For instance, the HT-PEMFC can be used at ambient pressure, i.e., without having a back pressure regulator. In this case, the variation in the atmospheric pressure directly affects pressures inside the fuel cell, which induces voltage variation. Moreover, in transient phases, several coupled phenomena can have an uncontrolled effect on the voltage. For example, following a change in the current operating point, thermal conditions in the fuel cell can vary, and the temperature stabilization then leads to a voltage variation. This article introduces a readjustment method for the fuel cell voltage to compensate for the effects of the pressure and temperature variations that are undergone and to decouple their effects. This methodology is based on the realization of a design of experiments to characterize the voltage sensitivity to pressure ([1; 1.5 bar]) and temperature ([120; 180 °C]) between 0.2 and 1 A/cm2 of an Advent PBI MEA (formerly BASF Celtec®-P 1100 W). The data obtained allowed identifying an empirical model that takes into account the aging caused by the experiment. Finally, the methodology is criticized before proposing an alternative method.Keywords
This publication has 33 references indexed in Scilit:
- A review of the development of high temperature proton exchange membrane fuel cellsChinese Journal of Catalysis, 2015
- High temperature (HT) polymer electrolyte membrane fuel cells (PEMFC) – A reviewJournal of Power Sources, 2013
- Degradation in phosphoric acid doped polymer fuel cells: A 6000 h parametric investigationInternational Journal of Hydrogen Energy, 2013
- Analyzing the Influence of H3PO4 as Catalyst Poison in High Temperature PEM Fuel Cells Using in-operando X-ray Absorption SpectroscopyThe Journal of Physical Chemistry C, 2013
- Degradation of high temperature MEA with PBI-H3PO4 membrane in a life testElectrochimica Acta, 2009
- A rapid break-in procedure for PBI fuel cellsInternational Journal of Hydrogen Energy, 2009
- Influence of the phosphoric acid-doping level in a polybenzimidazole membrane on the cell performance of high-temperature proton exchange membrane fuel cellsJournal of Power Sources, 2009
- Properties of high-temperature PEFC Celtec®-P 1000 MEAs in start/stop operation modeJournal of Power Sources, 2008
- Modelling and experimental validation of a high temperature polymer electrolyte fuel cellJournal of Applied Electrochemistry, 2007
- Effect of open circuit voltage on performance and degradation of high temperature PBI–H3PO4 fuel cellsJournal of Power Sources, 2006