A soluble factor (EMMPRIN) in exudate influences knee motion after total arthroplasty
- 17 December 2008
- journal article
- knee
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 17 (3) , 298-304
Abstract
Few studies have been conducted to investigate biological factors that affect postoperative knee motion after total knee arthroplasty (TKA). The purpose of this study is to test the hypothesis that range of knee motion (ROM) at 4 weeks after TKA is correlated with the concentration of extracellular matrix metalloproteinase inducer (EMMPRIN) and transforming growth factor (TGF)‐beta1 in the exudative fluid harvested from the joint after surgery. A prospective measurement study was conducted with 20 osteoarthritis patients who underwent TKA. At 48 h after surgery, the exudate was harvested from a closed drainage system. Enzyme‐linked immunosorbent assay was performed to measure the concentration of TGF‐beta1, EMMPRIN, MMP‐1, 2, 9, tissue inhibitor of metalloproteinase‐1, and Hyalunonan. Knee flexion angle was measured before and at 4 weeks after surgery. There was a significant correlation between the EMMPRIN levels and knee flexion angle (r = 0.557, p = 0.0148). Western blot analysis of the exudate showed a prominent band for EMMPRIN at 27 kDa. On the other hand, there was no correlation between the TGF‐beta1 levels and the knee flexion angle. This study showed that EMMPRIN levels after TKA affect the postoperative ROM. As to clinical relevance, EMMPRIN in the exudate after TKA is a promising biological indicator to predict difficulty in restoring postoperative ROM.Keywords
This publication has 46 references indexed in Scilit:
- Total Knee Arthroplasty With Cruciate-Retention-Type Alumina Ceramic Condylar ProsthesisTechniques in Knee Surgery, 2007
- Myofibroblast Upregulators are Elevated in Joint Capsules in Posttraumatic ContracturesClinical Orthopaedics and Related Research, 2007
- Joint capsule matrix turnover in a rabbit model of chronic joint contractures: Correlation with human contracturesJournal of Orthopaedic Research, 2006
- The NH2-terminal peptide of α–smooth muscle actin inhibits force generation by the myofibroblast in vitro and in vivoJournal of Cell Biology, 2002
- Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritisThe Journal of Bone and Joint Surgery. British volume, 1997
- Aggrecan is degraded by matrix metalloproteinases in human arthritis. Evidence that matrix metalloproteinase and aggrecanase activities can be independent.Journal of Clinical Investigation, 1996
- Rehabilitation After Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Tradeoffs between motion and stability in posterior substituting knee arthroplasty designJournal of Biomechanics, 1995
- Preoperative FlexionClinical Orthopaedics and Related Research, 1992
- Purification and characterization of hyaluronidase from Streptococcus dysgalactiae.Agricultural and Biological Chemistry, 1989