Acute Phase Response and Non-Reproducible Elevated Concentrations with a High-Sensitivity Cardiac Troponin I Assay
Open Access
- 2 March 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (5) , 1014
Abstract
High-sensitivity cardiac troponin (hs-cTn) testing has enabled physicians to make earlier diagnostic and prognostic decisions in the hospital setting than previous cardiac troponin assays. Analytical improvements have permitted one to measure cardiac troponin precisely in the nanogram per litre (ng/L) range with hs-cTn assays which has resulted in fast 0/1-h and 0/2-h algorithms for ruling-in and ruling-out myocardial infarction. Although analytical interferences that affect the reporting of hs-cTn are uncommon, not all hs-cTn assays are designed the same nor have undergone the same clinical and analytical validations. Here, after investigating an initial case of discrepant hs-cTnI results, we report that patients with an acute phase response (e.g., patients with inflammatory or infectious illnesses) can yield high and non-reproducible results with the Ortho Clinical Diagnostics hs-cTnI assay. Compared to Abbott Diagnostics hs-cTnI, Ortho Clinical Diagnostics hs-cTnI assay misclassifies biochemical injury in approximately 10% of the population being assessed for myocardial injury with imprecise results in approximately half of this population (i.e., 5%). In conclusion, caution is warranted in interpreting Ortho Clinical Diagnostics hs-cTnI alone in patients being evaluated for myocardial injury, especially in patients whose primary presentation is related to an acute phase response and not an acute coronary syndrome symptom.Keywords
Funding Information
- Canadian Institutes of Health Research (Project Grants)
This publication has 33 references indexed in Scilit:
- High sensitivity, contemporary and point-of-care cardiac troponin assays: educational aids developed by the IFCC Committee on Clinical Application of Cardiac Bio-MarkersClinical Chemistry and Laboratory Medicine (CCLM), 2019
- High-Sensitivity Generation 5 Cardiac Troponin T Sex- and Age-Specific 99th Percentiles in the CALIPER Cohort of Healthy Children and AdolescentsClinical Chemistry, 2019
- External Quality Assessment Testing Near the Limit of Detection for High-Sensitivity Cardiac Troponin AssaysClinical Chemistry, 2018
- Prospective Validation of the 0/1-h Algorithm for Early Diagnosis of Myocardial InfarctionJACC, 2018
- Clinical Laboratory Practice Recommendations for the Use of Cardiac Troponin in Acute Coronary Syndrome: Expert Opinion from the Academy of the American Association for Clinical Chemistry and the Task Force on Clinical Applications of Cardiac Bio-Markers of the International Federation of Clinical Chemistry and Laboratory MedicineClinical Chemistry, 2018
- Diagnostic Accuracy of a New High-Sensitivity Troponin I Assay and Five Accelerated Diagnostic Pathways for Ruling Out Acute Myocardial Infarction and Acute Coronary SyndromeAnnals of Emergency Medicine, 2018
- High-Sensitivity Cardiac Troponin Risk Cutoffs for Acute Cardiac Outcomes at Emergency Department PresentationCanadian Journal of Cardiology, 2017
- A practical approach for the validation and clinical implementation of a high-sensitivity cardiac troponin I assay across a North American cityPractical Laboratory Medicine, 2015
- Age- and Sex-Dependent Upper Reference Limits for the High-Sensitivity Cardiac Troponin T AssayJACC, 2014
- Effect of population selection on 99th percentile values for a high sensitivity cardiac troponin I and T assaysClinical Biochemistry, 2013