Effect of delayed entry on performance of the BACT/ALERT FAN PLUS bottles in the BACT/ALERT VIRTUO blood culture system
Authors:
Open Access
- 9 October 2020
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 40 (4) , 699-705
Abstract
Delayed entry of patient blood culture samples into a microbial detection system is unavoidable at times, due to off-shift staffing or transporting samples to centralized laboratories. Pre-incubation time and temperature of blood culture bottles are the most critical factors impacting recovery and detection of microorganisms. A total of 1377 BACT/ALERT® (BTA) Fastidious Antimicrobial Neutralization (FAN® PLUS) bottles (FA PLUS, FN PLUS, and PF PLUS) were tested after delayed entry times of 24 and 36 h at 20–25 °C (room temperature, RT) prior to loading into the BACT/ALERT® VIRTUO® microbial detection system (VIRTUO). Clinically relevant organisms were inoculated into bottles with 5–84 colony forming units (CFU) per bottle, and human blood (0 to 10 mL), and then loaded into the VIRTUO. When bottles were loaded without delay, a mean time to detection (TTD) of 9.6 h was observed. For delayed bottles, the TTD reported by the VIRTUO was added to the 24-h and 36-h delay times and resulted in average time to results of 32.5 h and 42.5 h, respectively. The FAN PLUS bottles in conjunction with the VIRTUO produced acceptable results when delays up to 24 h at 20–25 °C occur in loading.Keywords
Funding Information
- bioMérieux, Inc
This publication has 30 references indexed in Scilit:
- Quality of blood culture testing - a survey in intensive care units and microbiological laboratories across four European countriesCritical Care, 2013
- Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock, 2012Intensive Care Medicine, 2013
- Comparison of 2 Blood Culture Media Shows Significant Differences in Bacterial Recovery for Patients on Antimicrobial TherapyClinical Infectious Diseases, 2012
- Microbiological Profile of Organisms Causing Bloodstream Infection in Critically Ill PatientsJournal of Clinical Medicine Research, 2012
- Effect of Overnight Storage of Blood Culture Bottles on Bacterial Detection Time in the BACTEC 9240 Blood Culture SystemJournal of Microbiology, Immunology and Infection, 2010
- Needle-to-Incubator Transport Time: Logistic Factors Influencing Transport Time for Blood Culture SpecimensJournal of Clinical Microbiology, 2009
- Duration of hypotension before initiation of effective antimicrobial therapy is the critical determinant of survival in human septic shock*Critical Care Medicine, 2006
- Effects of Delayed-Entry Conditions on the Recovery and Detection of Microorganisms from BacT/ALERT and BACTEC Blood Culture BottlesJournal of Clinical Microbiology, 2006
- Comparison of the effect of delayed entry into 2 different blood culture systems (BACTEC 9240 and BacT/ALERT 3D) on culture positivityDiagnostic Microbiology and Infectious Disease, 2006
- Sensitivity of the BacT/ALERT FA-medium for detection of Pseudomonas aeruginosa in pre-incubated blood cultures and its temperature-dependenceJournal of Medical Microbiology, 2004