Utilization of Iron Lathe Waste and Post-Tensioned Steel Reinforcement in Lightweight Concrete Ribbed Slabs

Authors:

Abstract
The ribbed slab unit system of lightweight concrete provided a lighter and stiffer than the equivalent conventional slab system. Ten ribbed slabs were tested under two-point load as simply supported up to the failure. In this work, the lightweight concrete was produced by omitting the coarse aggregate and increasing the fine materials, approaching to a desired strength- to-density ratio. All the slabs have the same area of the cross-section and the steel reinforcement ratio. The studied parameters were a ratio of the rib depth to the overall section depth, volumetric fraction ratio of iron lathe waste, and use post-tensioned steel wires as an additional tension reinforcement. A mechanical drag technique was used to apply the initial prestress force in the post-tension system. The results showed that the increase in the rib depth to the overall section depth ratio increased the ultimate load capacity by (54.17%) up to certain limits. Also, the use of iron lathe waste improved the load-carrying capacity by about (40.54%). It was found that the better ratio of the rib depth to the overall section depth was approached to (0.835), and the ratio of iron lathe waste of (2%) was suitable without the occurrence of balling and agglomeration. On the other hand, the use of lightweight concrete as a prestressed concrete led to a clear improvement in the structural performance of the slabs. The load factor that represents the ratio of ultimate strength to the service load was found approximately equal to (4).

This publication has 12 references indexed in Scilit: