Accuracy improvement of quantitative LIBS analysis using wavelet threshold de-noising
- 6 February 2017
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (3) , 629-637
Abstract
Laser-induced breakdown spectroscopy (LIBS) is becoming a rapid and easy technique for quantitative elemental analysis. However, the implementation of accurate quantitative LIBS analysis is always subject to noise interference. In this work, in order to improve LIBS analysis performance for trace elements in aluminium alloys, a modified trade-off soft and hard threshold method is proposed based on the wavelet theory, where optimal parameters are deduced to eliminate noise interference. By using the modified algorithm combined with an Al I line at 308.215 nm as an internal standard, the statistical parameters including the determination coefficient (R2), the root mean square error (RMSE) and the relative standard deviation (RSD) of magnesium (Mg), manganese (Mn) and cuprum (Cu) in aluminium alloys are all significantly improved. The most significant improvement of R2 is 0.066 for Cu. The maximum RMSE reduction value is 0.583 for Mg, and the mean value of RMSE reduction is 0.261 for all three trace elements. And after de-noising, the value of RSD gets smaller for each trace element. Such results indicate that the optimized algorithm is valid for the effective improvement of the accuracy of quantitative LIBS analysis in the trace element determination of aluminium alloys.Keywords
Funding Information
- National Natural Science Foundation of China (No. 61605134)
This publication has 42 references indexed in Scilit:
- Incorporation of Support Vector Machines in the LIBS Toolbox for Sensitive and Robust Classification Amidst Unexpected Sample and System VariabilityAnalytical Chemistry, 2012
- Laser Induced Breakdown Spectroscopy for Elemental Analysis in Environmental, Cultural Heritage and Space Applications: A Review of Methods and ResultsSensors, 2010
- Improving laser-induced breakdown spectroscopy (LIBS) performance for iron and lead determination in aqueous solutions with laser-induced fluorescence (LIF)Journal of Analytical Atomic Spectrometry, 2009
- Robust Calibration with Respect to Background VariationApplied Spectroscopy, 2001
- Asymptotic behavior of the minimum mean squared error threshold for noisy wavelet coefficients of piecewise smooth signalsIEEE Transactions on Signal Processing, 2001
- A mathematical theory of communicationACM SIGMOBILE Mobile Computing and Communications Review, 2001
- Comparison of wavelet transform and Fourier self-deconvolution (FSD) and wavelet FSD for curve fittingThe Analyst, 2000
- Wavelet Denoising of Infrared SpectraThe Analyst, 1997
- De-noising by soft-thresholdingIEEE Transactions on Information Theory, 1995
- Decomposition of Hardy Functions into Square Integrable Wavelets of Constant ShapeSIAM Journal on Mathematical Analysis, 1984