Abstract
Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.Keywords
This publication has 10 references indexed in Scilit:
- The degree of knowledge shown by physicians in relation to the variability of laboratory test resultsClinical Chemistry and Laboratory Medicine (CCLM), 2009
- Proposed classification of various limit values (guide values) used in assisting the interpretation of quantitative laboratory test resultsClinical Chemistry and Laboratory Medicine (CCLM), 2009
- SI or non-SI units – which better match day-to-day imprecision?Clinical Chemistry and Laboratory Medicine (CCLM), 2008
- Pre-analytical variation of some haematological quantitiesClinical Chemistry and Laboratory Medicine (CCLM), 2008
- A plea for intra-laboratory reference limits. Part 2. A bimodal retrospective concept for determining reference limits from intra-laboratory databases demonstrated by catalytic activity concentrations of enzymesClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Objective determination of appropriate reporting intervalsAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2004
- Software for illustrative presentation of basic clinical characteristics of laboratory tests - GraphROC for WindowsScandinavian Journal of Clinical and Laboratory Investigation, 1995
- Expression of random analytical error as a precentage of the range of clinical interest.Clinical Chemistry, 1976
- Precision in a clinical chemistry laboratoryJournal of Clinical Pathology, 1967
- Lognormal DistributionsNature, 1945