Abstract
This work investigated the change in pressure drop in spinning cone columns with varying liquid and gas flow rates, and the physical processes that underlie this behavior were studied. The flow regimes include pre-loading, loading, and flooding. The boundaries between these regimes can be specified in terms of a dynamic (force-based) Froude number (FrLG), reflecting the inertial-gravity force balance of the liquid-gas mixture. Loading occurs above a FrLG value of 0.1 and flooding above FrLG of unity. The criteria of FrLG = 0.1 for loading and FrLG of unity for flooding agree with the experimental data and with the earlier correlation of the data in an SLE-type chart form. Using a rotation- and gravity-related normalization of variables, the normalized increase in the pressure drop due to liquid (ΔPL) is transformed into a function of the kinematic (velocity-based) Froude number FrG, where FrG = QG/A√(gPC), and QG is the volumetric gas flow rate, A is an appropriately defined area, g is the acceleration due to gravity, and PC is the cone pitch. Pressure-drop data for a small spinning cone column have been analyzed, where this equipment has a diameter of 0.148 m, a range of rotational speeds from 500 to 1500 rpm, and gas and liquid flow rates up to 300 L min−1 and 1.5 L min−1, respectively. For this equipment, ΔPL = 3.26 FrG 2 in the pre-loading regime and ΔPL = 0.093 FrG 6 in the loading regime, with these correlations explaining 73% and 79%, respectively, of the variation in the experimental data. Based on these approximations, dimensional diagrams of the liquid load regimes have been constructed that may be used to guide the design and operation of different-sized columns.

This publication has 3 references indexed in Scilit: