Volume of blood submitted for culture from neonates
Authors:
- P R NealPNP R Neal
- M B KleimanMKM B Kleiman
- J K ReynoldsJRJ K Reynolds
- S D AllenSAS D Allen
- J A LemonsJLJ A Lemons
- P L YuPYP L Yu
- 1 September 1986
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 24 (3) , 353-356
Abstract
We prospectively examined 298 sets (298 aerobic, 299 anaerobic, and 73 resin cultures) of blood cultures from 161 critically ill newborns. The attending physicians were unaware of the study. The mean blood volume per patient (aerobic and anaerobic) was 1.05 (range, 0.11 to 3.04) ml. The mean blood volume per aerobic bottle was 0.53 (range, 0.01 to 1.90) ml. Among aerobic samples 2.7% were less than or equal to 0.1 ml, 16% were less than or equal to 0.3 ml, 33% were less than or equal to 0.4 ml, and 55% were less than or equal to 0.5 ml. For anaerobic cultures the mean blood volume was 0.52 (range, 0.01 to 1.79) ml. Among anaerobic samples 2.7% were less than or equal to 0.1 ml, 15% were less than or equal to 0.3 ml, 35% were less than or equal to 0.4 ml, and 58% were less than or equal to 0.5 ml. Blood volume did not correlate with gestational age, chronologic age, or weight. The mean volume of blood submitted in positive cultures was not significantly greater than that in negative cultures. The blood volume used for culture from ill newborns may be inadequate for detecting sepsis, and the adequacy of currently available culture methods needs to be assessed for the small samples submitted from critically ill newborns.Keywords
This publication has 9 references indexed in Scilit:
- Rapid detection of bacteremia in children with a modified lysis direct plating methodJournal of Clinical Microbiology, 1985
- Specimen volume versus yield in the BACTEC blood culture systemJournal of Clinical Microbiology, 1985
- Evaluation of a lysis direct plating method for pediatric blood culturesJournal of Clinical Microbiology, 1985
- Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in childrenJournal of Clinical Microbiology, 1984
- Neonatal Heelstick Blood CulturePediatrics, 1980
- Evaluation of blood culture procedures in a pediatric hospitalJournal of Clinical Microbiology, 1979
- Diagnosis of neonatal bacteremia by a microblood culture techniqueThe Journal of Pediatrics, 1977
- Effect of volume of blood cultured on detection of bacteremiaJournal of Clinical Microbiology, 1976
- Neonatal escherichia coli septicemia—bacterial counts in bloodThe Journal of Pediatrics, 1974