Outbreak of Pseudomonas aeruginosa Surgical Site Infections after Arthroscopic Procedures: Texas, 2009
Authors:
- Pritish K. ToshPTPritish K. Tosh
- Jonathan M. DuffyJDJonathan M. Duffy
- Gary HeseltineGHGary Heseltine
- Arjun SrinivasanASArjun Srinivasan
- Carolyn V. GouldCGCarolyn V. Gould
- Sandra I. Berríos-TorresSBSandra I. Berríos-Torres
- 1 December 2011
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 32 (12) , 1179-1186
Abstract
Setting.: Seven organ/space surgical site infections (SSIs) that occurred after arthroscopic procedures and were due to Pseudomonas aeruginosa of indistinguishable pulsed-field gel electrophoresis (PFGE) patterns occurred at hospital X in Texas from April 22, 2009, through May 7, 2009.Objective.: To determine the source of the outbreak and prevent future infections.Design.: Infection control observations and a case-control study.Methods.: Laboratory records were reviewed for case finding. A case-control study was conducted. A case patient was defined as someone who underwent knee or shoulder arthroscopy at hospital X during the outbreak period and subsequently developed organ/space SSI due toP. aeruginosa. Cultures of environmental and surgical equipment samples were performed, and selected isolates were analyzed by PFGE. Surgical instrument reprocessing practices were reviewed, and surgical instrument lumens were inspected with a borescope after reprocessing to assess cleanliness.Results.: The case-control study did not identify any significant patient-related or operator-related risk factors. P. aeruginosa grew from 62 of 388 environmental samples. An isolate from the gross decontamination sink had a PFGE pattern that was indistinguishable from that of the case patient isolates. All surgical instrument cultures showed no growth. Endoscopic evaluation of reprocessed arthroscopic equipment revealed retained tissue in the lumen of both the inflow/outflow cannulae and arthroscopic shaver handpiece. No additional cases occurred after changes in instrument reprocessing protocols were implemented. After this outbreak, the US Food and Drug Administration released a safety alert about the concern regarding retained tissue within arthroscopic shavers.Conclusions.: These SSIs were likely related to surgical instrument contamination with P. aeruginosa during instrument reprocessing. Retained tissue in inflow/outflow cannulae and shaver handpieces could have allowed bacteria to survive sterilization procedures.Keywords
This publication has 11 references indexed in Scilit:
- Instrumentation-Specific Infection After Anterior Cruciate Ligament ReconstructionSports Health: A Multidisciplinary Approach, 2009
- Surgical site infections after arthroscopy: Outbreak investigation and case control studyArthroscopy, 2003
- An Unusual Epidemic of Staphylococcus ‐Negative Infections Involving Anterior Cruciate Ligament Reconstruction With Salvage of the Graft and FunctionArthroscopy, 2000
- Outcomes of Postoperative Septic Arthritis After Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 1999
- Septic Arthritis Following Arthroscopic Meniscus Repair: A Cluster of Three CasesArthroscopy, 1999
- Septic arthritis after arthroscopy: The contributing roles of intraarticular steroids and environmental factorsAmerican Journal of Infection Control, 1994
- Septic arthritis following arthroscopy: Clinical syndromes and analysis of risk factorsArthroscopy, 1992
- Septic arthritis following arthroscopy, with cost/benefit analysis of antibiotic prophylaxisArthroscopy, 1988
- Hospital-acquired infections after arthroscopic knee surgery: A probable environmental sourceAmerican Journal of Infection Control, 1987
- Two per cent glutaraldehydeJournal of Bone and Joint Surgery, 1982