Multislice dark‐blood carotid artery wall imaging: A 1.5 T and 3.0 T comparison
- 22 March 2006
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 23 (5) , 699-705
Abstract
Purpose To compare two multislice turbo spin‐echo (TSE) carotid artery wall imaging techniques at 1.5 T and 3.0 T, and to investigate the feasibility of higher spatial resolution carotid artery wall imaging at 3.0 T. Materials and Methods Multislice proton density‐weighted (PDW), T2‐weighted (T2W), and T1‐weighted (T1W) inflow/outflow saturation band (IOSB) and rapid extended coverage double inversion‐recovery (REX‐DIR) TSE carotid artery wall imaging was performed on six healthy volunteers at 1.5 T and 3.0 T using time‐, coverage‐, and spatial resolution–matched (0.47 × 0.47 × 3 mm3) imaging protocols. To investigate whether improved signal‐to‐noise ratio (SNR) at 3.0 T could allow for improved spatial resolution, higher spatial resolution imaging (0.31 × 0.31 × 3 mm3) was performed at 3.0 T. Carotid artery wall SNR, carotid lumen SNR, and wall‐lumen contrast‐to‐noise ratio (CNR) were measured. Results Signal gain at 3.0 T relative to 1.5 T was observed for carotid artery wall SNR (223%) and wall‐lumen CNR (255%) in all acquisitions (P < 0.025). IOSB and REX‐DIR images were found to have different levels of SNR and CNR (P < 0.05) with IOSB values observed to be larger. Normalized to a common imaging time, the higher spatial resolution imaging at 3.0 T and the lower spatial resolution imaging at 1.5 T provided similar levels of wall‐lumen CNR (P = NS). Conclusion Multislice carotid wall imaging at 3.0 T with IOSB and REX‐DIR benefits from improved SNR and CNR relative to 1.5 T, and allows for higher spatial resolution carotid artery wall imaging. J. Magn. Reson. Imaging 2006.Keywords
This publication has 16 references indexed in Scilit:
- Comparison of gated and nongated fast multislice black‐blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniquesJournal of Magnetic Resonance Imaging, 2005
- Assessment of Human Atherosclerotic Carotid Plaque Components with Multisequence MR Imaging: Initial ExperienceRadiology, 2005
- Musculoskeletal MRI at 3.0 T: Relaxation Times and Image ContrastAmerican Journal of Roentgenology, 2004
- Double inversion black‐blood fast spin‐echo imaging of the human heart: A comparison between 1.5T and 3.0TJournal of Magnetic Resonance Imaging, 2003
- In vivo accuracy of multisequence MR imaging for identifying unstable fibrous caps in advanced human carotid plaquesJournal of Magnetic Resonance Imaging, 2003
- Multislice double inversion‐recovery black‐blood imaging with simultaneous slice reinversionJournal of Magnetic Resonance Imaging, 2003
- Characterization of Atherosclerotic Plaques by Magnetic Resonance ImagingAnnals of the New York Academy of Sciences, 2000
- Phased‐Array Magnetic Resonance Imaging of the Carotid Artery Bifurcation: Preliminary Results in Healthy Volunteers and a Patient with Aherosclerotic DiseaseJournal of Magnetic Resonance Imaging, 1995
- Flow patterns in the human carotid artery bifurcation.Stroke, 1984
- Pulsatile flow in a model carotid bifurcation.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1983