Control of EOF in CE by different ways of application of radial electric field
- 21 February 2007
- journal article
- Published by Wiley in Electrophoresis
- Vol. 28 (5) , 756-766
Abstract
Various ways of application of radial electric field for the control of electrokinetic potential and EOF in a home‐made device for CE are presented. The device comprises three high‐voltage power supplies, which are used to form a radial electric field across the fused‐silica capillary wall. One power supply provides the internal electric field – a driving force for electrophoretic migration of charged analytes and for the EOF. Two power supplies are connected to the ends of the outer low‐conductivity polymeric coating, which is formed by the dispersion of insoluble conductive copolymer of aniline and p‐phenylendiamine in polystyrene matrix (dissolved in N‐methylpyrrolidone) attached to the original outer polyimide coating of the capillary. They are able to constitute the external longitudinal electric field with variable values of electric potential at both ends of the outer coating. The potential gradient between the external and internal electric field is perpendicular to the capillary wall and forms a radial electric field across the capillary wall, which affects the electrokinetic potential at the solid–liquid interface and EOF inside the capillary. The developed device and methodology has been applied for the analysis of both chiral and achiral molecules such as terbutaline enantiomers and oligopeptides (diglycine and triglycine). The effect of magnitude, orientation, and different ways of application of the radial electric field on the flow rate of the EOF and on the speed, efficiency, and resolution of CZE separations of the above analytes in the internally noncoated fused‐silica capillaries have been evaluated.Keywords
This publication has 49 references indexed in Scilit:
- Band‐broadening in capillary zone electrophoresis with axial temperature gradientsElectrophoresis, 2004
- Joule heating effect on electroosmotic flow and mass species transport in a microcapillaryInternational Journal of Heat and Mass Transfer, 2004
- The state of the art of dynamic coatingsElectrophoresis, 2001
- Polymer wall coatings for capillary electrophoresisElectrophoresis, 2001
- Capillary electrophoresis of small solutes in linear polymer solutions: Relation between ionic mobility, diffusion coefficient and viscosityElectrophoresis, 1999
- Improving Resolution in Capillary Zone Electrophoresis through Bulk Flow ControlMicrochemical Journal, 1999
- Dependence of analyte separation on electroosmotic flow in capillary zone electrophoresis: Quantitative description by the reduced mobilityJournal of Microcolumn Separations, 1998
- Limitations of the optimization of the resolution by the buffer pH in capillary zone electrophoresisAnalytical and Bioanalytical Chemistry, 1994
- Fundamental and practical aspects of coupled capillaries for the control of electroosmotic flow in capillary zone electrophoresis of proteinsJournal of Chromatography A, 1993
- Radial pH distribution during capillary electrophoresis with electroosmotic flow: Analysis with high ionic strength buffersJournal of Chromatography A, 1992