Suppression of Intravascular Signal on Fat-saturated Contrast-enhanced Thoracic MR Arteriograms
Authors:
- Evan S. SiegelmanESEvan S. Siegelman
- Riad CharafeddineRCRiad Charafeddine
- Alan H. StolpenASAlan H. Stolpen
- Leon AxelLALeon Axel
- 1 October 2000
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 217 (1) , 115-118
Abstract
To assess the prevalence of artifactual signal intensity loss within the aortic arch and proximal branch vessels on fat-saturated contrast material-enhanced magnetic resonance (MR) arteriograms of the thoracic aorta and to hypothesize about the cause of the loss of signal intensity. Between January and June 1998, 105 consecutive MR arteriograms of the thoracic aorta were acquired in 103 patients at 1.5 T. Imaging included an arterial phase three-dimensional (3D) fat-saturated contrast-enhanced gradient-echo (GRE) sequence followed by a delayed two-dimensional (2D) transverse fat-saturated GRE sequence. All MR images were reviewed by two radiologists who were blinded to patient history and results of imaging studies and who evaluated the images for the presence of intraluminal loss of signal intensity in the aortic arch and the proximal branch vessels. Intravascular loss of signal intensity was present in at least one vessel on 23 of the 105 arterial phase 3D studies. Seventy-one of 91 left subclavian arterial segments had loss of signal intensity on the delayed 2D studies. Intravascular signal intensity loss can be present on contrast-enhanced fat-saturated images of the aortic arch and proximal branch vessels, particularly the left subclavian artery. This phenomenon, which is to the authors' knowledge previously unreported and which is hypothesized to result from undesired water saturation, should not be misinterpreted as stenotic or occlusive vascular disease.Keywords
This publication has 10 references indexed in Scilit:
- Comparison of short inversion time inversion recovery (STIR) and fat-saturated (chemsat) techniques for background fat intensity suppression in cervical and thoracic MR imagingJournal of Magnetic Resonance Imaging, 2000
- MR IMAGING TECHNIQUES OF THE LIVERRadiologic Clinics of North America, 1998
- Thoracic MR aortography: imaging techniques and strategies.RadioGraphics, 1998
- Intraluminal signal intensity of iliac artery stents investigated by contrast-enhanced three-dimensional MR angiographyComputerized Medical Imaging and Graphics, 1998
- Three-dimensional contrast-enhanced magnetic resonance angiography of the thoracic vasculatureEuropean Radiology, 1997
- Frequency-Selective Fat Suppression MR ImagingJournal of Neuro-Ophthalmology, 1997
- Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging.Radiology, 1997
- Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta.American Journal of Roentgenology, 1996
- Unsuppressed fat in the right anterior diaphragmatic region on fat‐suppressed T2‐weighted fast spin‐echo MR imagesJournal of Magnetic Resonance Imaging, 1995
- Gadolinium-enhanced MR aortography.Radiology, 1994