Oxygen Transfer of Fine-Bubble Aeration in Activated Sludge Treating Saline Industrial Wastewater
Open Access
Abstract
Aeration is usually the most energy-intensive part of the activated sludge process, accounting for 50% to 80% of the total requirement. To achieve high efficiency, designers and operators of WWTPs must, therefore, consider all influencing factors, including salinity. With increasing salinity, oxygen transfer increases compared to tap water (TW), due to the inhibition of bubble coalescence. Previous saline water (SW) experiments showed that by using small slits in the diffuser membrane design, oxygen transfer and aeration efficiency increase further. In this study, we present a modified approach for considering the salt effect on oxygen transfer and assess the transferability of SW results to saline-activated sludge (sAS) conditions. Therefore, we operated a pilot-activated sludge plant over 269 days with a saline industrial wastewater influent. The oxygen transfer of disc-diffusers with two different membrane designs was measured continuously via the off-gas method. The salt concentration (cSalt) measured via ion analysis ranged between 4.9 and 11 g/L. Despite a high cSalt fluctuation, COD elimination was >90% all the time. Our results confirm previous SW results. Oxygen transfer in sAS is up to three times higher compared to non-saline conditions. Aeration efficiency shows that despite a higher pressure drop, diffusers with smaller slits are to be recommended in order to improve aeration in sAS.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (02WAV1409A)
This publication has 25 references indexed in Scilit:
- Oxygen Transfer Parameter Estimation: Impact of MethodologyJournal of Environmental Engineering, 2012
- Effect of Electrolytes in Aqueous Solution on Bubble Size in Gas–Liquid Bubble ColumnsIndustrial & Engineering Chemistry Research, 2011
- Optimization of WWTP aeration process upgrades for energy efficiencyWater Practice & Technology, 2011
- Assessment of diffuser pressure loss on WWTPs in Baden-WürttembergWater Science & Technology, 2011
- The influence of electrolytes on gas hold-up and regime transition in bubble columnsChemical Engineering Science, 2007
- Biomass effects on oxygen transfer in membrane bioreactorsWater Research, 2007
- Effects of Sodium Chloride on the Performance of a Sequencing Batch ReactorJournal of Environmental Engineering, 2005
- Effect of flotation frothers on bubble size and foam stabilityInternational Journal of Mineral Processing, 2002
- The studies on the oxygen mass transfer coefficient in a bioreactorProcess Biochemistry, 2001
- Coalescence of gas bubbles in aqueous solutions of inorganic electrolytesChemical Engineering Science, 1967