Soft starting method for single-phase PWM AC chopper fed three-phase induction motor
Authors:
- 1 October 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1991-1995
Abstract
This paper presents a soft starting method for a three phase induction motor operating from a single-phase PWM AC chopper in order to reduce high starting current caused by direct on line (DOL) starting. The MATLAB/Simulink is used for simulation. The motor stator windings are connected in a delta form with an external capacitor for operating from a single phase supply. With the proposed method, the initial voltage and ramping of voltage with a desired rate can be adjusted in order to obtain appropriate starting time and starting torque. The results of the simulation show that the motor starting current can be reduced and the capacitor value affects the starting time.Keywords
This publication has 5 references indexed in Scilit:
- PWM AC chopper control schemes for energy saving of single-phase induction motors2012
- Three-phase induction motor operating from single-phase supply with an electronically controlled capacitorElectric Power Systems Research, 2005
- AC chopper voltage controller-fed single-phase induction motor employing symmetrical PWM control techniqueElectric Power Systems Research, 2000
- A maximum torque control with a controlled capacitor for a single-phase induction motorIEEE Transactions on Industrial Electronics, 1995
- Transient Analysis of A Three Phase Induction Motor with Single Phase SupplyIEEE Transactions on Power Apparatus and Systems, 1983