Optimal placement of electrodes in an electroporation process
Open Access
- 1 August 2010
- journal article
- Published by EDP Sciences in ESAIM: Proceedings
- Vol. 30, 34-43
Abstract
Electroporation consists in increasing the permeability of a tissue by applying high voltage pulses. In this paper we discuss the question of optimal placement and optimal loading of electrodes such that electroporation holds only in a given open set of the domain. The electroporated set of the domain is where the norm of the electric field is above a given threshold value. We use a standard gradient algorithm to optimize the loading of the electrodes and shape sensitivity analysis and a gradient algorithm in order to move the electrodes. We also discuss the choice of objective functions to be chosen in the gradient algorithm. Résumé. L'électroporation est un procédé qui consiste à augmenter la perméabilité d'un tissu en le soumettant à des pulses électriques de grande amplitude. L'objet de ce papier est d' étudier l'optimisation du placement des électrodes afin d'électroporer une région d'un domaine d'étude. La partie électroporée est celle où la norme du champ électrique dépasse une valeur seuil. Nous utilisons une méthode de gradient standard afin d'optimiser la charge des électrodes. L'optimisation du placement des électrodes est effectuée à l'aide d'une dérivation de domaine et d'un algorithme de gradient. Nous concluons par des simulations qui illustrent l'efficacité de la méthode proposée.Keywords
This publication has 11 references indexed in Scilit:
- An e-learning application on electrochemotherapyBioMedical Engineering OnLine, 2009
- Numerical Analysis of a Finite Element/Volume Penalty MethodSIAM Journal on Numerical Analysis, 2009
- Analytical and numerical quantification and comparison of the local electric field in the tissue for different electrode configurationsBioMedical Engineering OnLine, 2007
- Electrochemotherapy – An easy, highly effective and safe treatment of cutaneous and subcutaneous metastases: Results of ESOPE (European Standard Operating Procedures of Electrochemotherapy) studyEuropean Journal of Cancer Supplements, 2006
- Conception optimale de structures2006
- Sequential Finite Element Model of Tissue ElectropermeabilizationIEEE Transactions on Biomedical Engineering, 2005
- Finite-element modeling of needle electrodes in tissue from the perspective of frequent model computationIEEE Transactions on Biomedical Engineering, 2003
- Time Courses of Mammalian Cell Electropermeabilization Observed by Millisecond Imaging of Membrane Property Changes during the PulseBiophysical Journal, 1999
- Chinese hamster ovary cells sensitivity to localized electrical stressesBioelectrochemistry and Bioenergetics, 1999
- Electroporation and electrophoretic DNA transfer into cells. The effect of DNA interaction with electroporesBiophysical Journal, 1992