An evaluation of near infrared spectroscopy and cryospectrophotometry estimates of haemoglobin oxygen saturation in a rodent mammary tumour model
- 25 August 2000
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (9) , 2685-2700
Abstract
Haemoglobin oxygen saturation in subcutaneous rat mammary tumours was measured using near infrared spectroscopy (NIRS) in vivo and in rapidly frozen sections from the same tumours using cryospectrophotometry, which reports oxygen saturation in individual blood vessels to depths of 4 mm from the tissue surface. Measurements were performed on tumours while animals breathed either room air or carbogen. In five of nine tumours, the average saturation calculated from cryospectrophotometric measurements agreed with that determined from NIRS to within 13%, and in four of these five tumours agreement was 5% or better. In the remaining four of nine tumours, where agreement was poor, the volume-averaged saturations estimated from NIRS were consistently higher than those calculated from cryospectrophotometry. Monte Carlo simulations demonstrated that the depth of tissue probed by NIRS was significantly greater than that sampled by cryospectrophotometry. Analysis of the frequency of severely hypoxic vessels showed that when NIRS reported a saturation of approximately 70% or higher, the fraction of tumour vessels with saturations less than 10% was limited to 0.06 or less. Sensitivity and specificity analysis suggests that NIRS and NIRS imaging may identify clinically relevant hypoxia, even when its spatial extent is below the resolution limit of the NIRS technique.Keywords
This publication has 22 references indexed in Scilit:
- Effects of chronic indomethacin therapy on the development and progression of spontaneous mammary tumors in C3H/HEJ miceInternational Journal of Cancer, 1997
- Design and testing of a white-light, steady-state diffuse reflectance spectrometer for determination of optical properties of highly scattering systemsApplied Optics, 1997
- Detection and characterization of optical inhomogeneities with diffuse photon density waves: a signal-to-noise analysisApplied Optics, 1997
- Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid mediumJournal of the Optical Society of America A, 1997
- Hypoxia-mediated selection of cells with diminished apoptotic potential in solid tumoursNature, 1996
- Boundary conditions for the diffusion equation in radiative transferJournal of the Optical Society of America A, 1994
- Refractive indices of water and ice in the 065- to 25-μm spectral rangeApplied Optics, 1993
- Cryospectrophotometric Determination of Tumor Intravascular Oxyhemoglobin Saturations: Dependence on Vascular Geometry and Tumor GrowthJNCI: Journal of the National Cancer Institute, 1988
- Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenationBiochimica et Biophysica Acta (BBA) - Bioenergetics, 1988
- The Concentration of Oxygen Dissolved in Tissues at the Time of Irradiation as a Factor in RadiotherapyBritish Journal of Radiology, 1953