Feasibility, Design, and Deployment Requirements of TCR for Bistatic SAR Radiometric Calibration
Open Access
- 10 October 2018
- journal article
- research article
- Published by MDPI AG in Remote Sensing
- Vol. 10 (10) , 1610
Abstract
The trihedral corner reflector (TCR) is widely used as the calibration device in monostatic synthetic aperture radar (SAR) calibration, and the performance of the TCR in radiometric calibration has been studied and verified in depth. As for the bistatic SAR system calibration problem, there have been few published studies. There is a lack of knowledge regarding the exact bistatic radar cross-section (RCS) pattern of TCR with different bistatic angles, and it is also not clear whether the TCR can be used as the calibration target in bistatic SAR. Moreover, the bistatic and monostatic radar cross-section (RCS) characteristics of the TCR are different, even if the bistatic angle is very small. Therefore, the feasibility, design, and deployment requirements of the TCR for bistatic SAR calibration should be carefully investigated. In this paper, we outline the theoretical and practical requirements that need to be satisfied when choosing appropriate calibration devices for bistatic radiometric calibration. Based on these requirements, we analyzed the bistatic RCS patterns using electromagnetic simulation, and concluded that the TCR is feasible for bistatic SAR calibration under relatively small bistatic angles (less than 6°). The change of TCR boresight with the bistatic angle is not considered generally. However, we found that the TCR boresight and peak RCS will change with the bistatic angle. We have also proposed that the bistatic angle can be extended to 20° by taking the change of the TCR boresight into account. In this condition, we should get the TCR boresight according to the bistatic angle and then align it during the deployment. Both of these two conditions have their own unique advantages. Different error sources of TCR RCS from manufacture, misalignment, and deformation were investigated quantitatively with simulations, which can provide a theoretical basis for how to design a suitable TCR and guarantee the calibration accuracy for bistatic calibration. In addition, simulation results are different from those of monostatic calibration. Through experiments, we have further verified the feasibility by comparing the quality of bistatic SAR images and point target energy with several typical bistatic angles as the TCR boresight is considered or not. If the bistatic angle is larger than 6°, taking the TCR optimum boresight into account can improve imaging quality and point target energy.Keywords
Funding Information
- Equipment Development Department Pre-Research Fund (6140416010202)
- National Natural Science Foundation of China (61771453)
This publication has 21 references indexed in Scilit:
- Active calibration target for bistatic radar cross‐section measurementsRadio Science, 2016
- Inflight Antenna Pattern Measurement for Bistatic Synthetic Aperture Radar SystemsIEEE Antennas and Wireless Propagation Letters, 2007
- ONERA-DLR bistatic SAR campaign: planning, data acquisition, and first analysis of bistatic scattering behaviour of natural and urban targetsIEE Proceedings - Radar, Sonar and Navigation, 2006
- An investigation of bistatic calibration techniquesIEEE Transactions on Geoscience and Remote Sensing, 2005
- Comparison of monostatic and bistatic radarlmagesIEEE Antennas and Propagation Magazine, 2003
- A cross-polarized bistatic calibration device for RCS measurementsIEEE Transactions on Antennas and Propagation, 2003
- Bistatic scattering characterization of complex objectsIEEE Transactions on Geoscience and Remote Sensing, 2000
- SAR calibration: an overviewIEEE Transactions on Geoscience and Remote Sensing, 1992
- Accuracy of using point targets for SAR calibrationIEEE Transactions on Aerospace and Electronic Systems, 1991
- Synthetic aperture radar calibration using reference reflectorsIEEE Transactions on Geoscience and Remote Sensing, 1990