Description and evaluation of a ventriculo-coronary artery bypass device that provides bi-directional coronary flow
Authors:
Open Access
- 1 January 2004
- journal article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 25 (1) , 43-50
Abstract
Objective: The objective of this study was to assess acute patency of a new myocardial revascularization device that connects the left ventricular cavity to a coronary artery (termed ventriculo-coronary artery bypass, VCAB) thereby providing proximal and distal blood flow from the site of the anastomosis. Methods: A device made of expanded polytetrafluoroethylene and low density polyethylene was implanted from the base of the left ventricle to the mid left anterior descending coronary artery (LAD) in 11 juvenile domestic pigs using a beating heart approach. Flow rates were measured in the distal LAD before and after implant using ultrasonic flow techniques, and patency was assessed at explant at either 2 or 4 weeks post-implantation. Myocardial perfusion using positron emission tomography (PET) was assessed in a separate set of pigs (n=2) revascularized by VCAB 2 weeks post-implant. Results: Net forward flow distal to the implanted device was 73±15% of native LAD flow. PET demonstrated that the target myocardium was perfused at 85% of that seen in the remote, control myocardium. Device patency rate was 80% (4/5) at 2 weeks in one set of pigs and 83% (5/6) at 4 weeks in a second set of pigs. Histologic analysis showed formation of neointima along the extraventricular segment of the device. Conclusions: This study demonstrates the promise of perfusing ischemic myocardium using a VCAB approach with a device that provides blood flow both proximal and distal to the anastomosis. Patency of the transmyocardial device was encouraging at 2 and 4 weeks and warrants further investigation.Keywords
This publication has 9 references indexed in Scilit:
- Ventriculocoronary artery bypass results using a mesh-tipped device in a porcine modelThe Annals of Thoracic Surgery, 2001
- Direct coronary artery perfusion from the left ventricleThe Journal of Thoracic and Cardiovascular Surgery, 2001
- North American Experience With the Perma-Flow Prosthetic Coronary GraftThe Annals of Thoracic Surgery, 1996
- Clinical and invasive 7-month follow-up of a patient with a synthetic coronary graftInternational Journal of Cardiology, 1995
- Regional myocardial perfusion and wall thickening during ischemia in conscious dogsAmerican Journal of Physiology-Heart and Circulatory Physiology, 1984
- Early and late patency of expanded polytetrafluoroethylene vascular grafts in aorta-coronary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1981
- Aorta-coronary artery revascularization with an expanded polytetrafluoroethylene vascular graftThe Journal of Thoracic and Cardiovascular Surgery, 1978
- Coronary bypass with Gore-Tex graftThe Journal of Thoracic and Cardiovascular Surgery, 1978
- Late Postoperative Anatomic Observations after Insertion of Hufnagel Caged-ball Prostheses in Descending Thoracic AortaChest, 1975