Degradation Analysis of Thin Mg-xAg Wires Using X-ray Near-Field Holotomography
Authors:
- Sebastian MeyerSMSebastian Meyer
- Andreas WolfAWAndreas Wolf
- Daniela SandersDSDaniela Sanders
- Kamila IskhakovaKIKamila Iskhakova
- Hanna ĆwiekaHĆHanna Ćwieka
- Stefan BrunsSBStefan Bruns
- Silja FlennerSFSilja Flenner
- Imke GrevingIGImke Greving
- Johannes HagemannJHJohannes Hagemann
- Regine Willumeit-RömerRWRegine Willumeit-Römer
- Björn WieseBjörn Wiese
- Berit Zeller-PlumhoffBZBerit Zeller-Plumhoff
Open Access
Abstract
Magnesium–silver alloys are of high interest for the use as temporary bone implants due to their antibacterial properties in addition to biocompatibility and biodegradability. Thin wires in particular can be used for scaffolding, but the determination of their degradation rate and homogeneity using traditional methods is difficult. Therefore, we have employed 3D imaging using X-ray near-field holotomography with sub-micrometer resolution to study the degradation of thin (250 μm diameter) Mg-2Ag and Mg-6Ag wires. The wires were studied in two states, recrystallized and solution annealed to assess the influence of Ag content and precipitates on the degradation. Imaging was employed after degradation in Dulbecco’s modified Eagle’s medium and 10% fetal bovine serum after 1 to 7 days. At 3 days of immersion the degradation rates of both alloys in both states were similar, but at 7 days higher silver content and solution annealing lead to decreased degradation rates. The opposite was observed for the pitting factor. Overall, the standard deviation of the determined parameters was high, owing to the relatively small field of view during imaging and high degradation inhomogeneity of the samples. Nevertheless, Mg-6Ag in the solution annealed state emerges as a potential material for thin wire manufacturing for implants.Keywords
All Related Versions
Funding Information
- H2020 Marie Skłodowska-Curie Actions (811226)
This publication has 28 references indexed in Scilit:
- Magnesium-Based Compression Screws: A Novelty in the Clinical Use of ImplantsJOM, 2016
- X-Ray Holographic Imaging of Hydrated Biological Cells in SolutionPhysical Review Letters, 2015
- TomoPy: a framework for the analysis of synchrotron tomographic dataJournal of Synchrotron Radiation, 2014
- Antibacterial biodegradable Mg-Ag alloys2013
- In vitro mechanical and corrosion properties of biodegradable Mg-Ag alloysMaterials and Corrosion, 2013
- Fiji: an open-source platform for biological-image analysisNature Methods, 2012
- The Manufacture of Resorbable Suture Material from Magnesium – Drawing and Stranding of Thin WiresAdvanced Engineering Materials, 2011
- The history of biodegradable magnesium implants: A review☆Acta Biomaterialia, 2010
- Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x raysApplied Physics Letters, 1999
- Ist das Magnesium als Naht-und Schienungsmaterial für Knochenoperationen geeignet?Archives of orthopaedic and trauma surgery, 1937