Abstract
This study aims to acquire an understanding of the fundamental feature of IJV and DV under heating operation. Full‐scale experiments were conducted under these two different systems and supply air conditions along with temperature distribution and ventilation effectiveness. A wall surface of the test room was cooled as a heating load, and heating elements simulating occupants were located as internal heat load and contaminant emission source. Three cases of supply temperature were tested and the flow rate was also varied correspondingly. The position of the supply terminal was also changed to see its effect on heating performance, that is, mounted on the interior/exterior wall. For DV, the temperature/contaminant distribution differed significantly depending on the supply conditions, while that of IJV remained almost the same as a perfect mixing condition. Generally, IJV can achieve better temperature distribution compared to DV; however, the ventilation effectiveness of DV was superior to that of IJV with large supply flow rate. The correlation between the Archimedes number based on supply conditions and indices expressing local temperature and ventilation effectiveness is obtained. For IJV, the position of the terminal was found to have a larger impact on air distribution than the supply flow rate, while the opposite feature was obtained for DV.Keywords
Funding Information
- Japan Society for the Promotion of Science (JP20J10608)
This publication has 20 references indexed in Scilit:
- Heating energy consumption of impinging jet ventilation and mixing ventilation in large-height spaces: A comparison studyEnergy and Buildings, 2016
- Displacement ventilation zonal model for particle distribution resulting from high momentum respiratory activitiesBuilding and Environment, 2015
- A review of the performance of different ventilation and airflow distribution systems in buildingsBuilding and Environment, 2014
- Investigation on the flow and thermal behavior of impinging jet ventilation systems in an office with different heat loadsBuilding and Environment, 2013
- A nodal model to predict vertical temperature distribution in a room with floor heating and displacement ventilationBuilding and Environment, 2013
- Numerical investigation of the flow behavior of an isothermal impinging jet in a roomBuilding and Environment, 2012
- Floor heating and cooling combined with displacement ventilation: Possibilities and limitationsEnergy and Buildings, 2010
- Experimental investigation of the velocity distribution of the attached plane jet after impingement with the corner in a high roomEnergy and Buildings, 2010
- Effect of door opening on the performance of displacement ventilation in a typical office buildingBuilding and Environment, 2007
- A ComparisonAJN, American Journal of Nursing, 1917