Adsorbent comparisons for anesthetic gas capture in hospital air emissions
- 24 May 2016
- journal article
- research article
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 51 (10) , 805-809
Abstract
For the development of emission control strategies, activated carbon, zeolite, molecular sieves, and a silica gel were tested for adsorption of the newer anesthetic gases isoflurane, sevoflurane, and desflurane from air. The activated carbon Norit GCA 48 was selected for the best performance, and adsorption isotherms at room temperature were developed for the three anesthetics. Equilibrium capacities for this carbon were in the range of 500 to 1,000 mg g−1 for these anesthetics at partial pressures ranging from 5 to 45 Torr, with the most volatile compound (desflurane) showing the least favorable adsorption. Activated carbons are therefore suggested for use as effective adsorbents in emission control of these anesthetic gases from hospitals.Keywords
This publication has 6 references indexed in Scilit:
- Environmental Implications of Anesthetic GasesAnesthesia Progress, 2012
- Anesthetic gases and global warming: Potentials, prevention and future of anesthesiaAnesthesia: Essays and Researches, 2011
- Adsorption Equilibria of CFC-115 on Activated CharcoalJournal of Chemical & Engineering Data, 2003
- Silica zeolite scavenging of exhaled isoflurane: A preliminary reportCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2002
- Adsorption equilibrium and catalytic reaction of CFC-115 on Pd/activated carbon powderCarbon, 1998
- Adsorption Characteristics of Volatile Anesthetics on Activated Carbons and Performance of Carbon CanistersAnesthesiology, 1977