Rigidity of commonly used dental trauma splints
- 15 May 2009
- journal article
- research article
- Published by Wiley in Dental Traumatology
- Vol. 25 (3) , 248-255
Abstract
Abstract – Background/Aims: The stability of immobilization devices varies from flexible to rigid, depending on the trauma. We evaluated the rigidity of various commonly used splints in vitroMaterial and Methods: An acrylic resin model was used. The central incisors simulated injured teeth, with increased vertical and horizontal mobility. The lateral incisors and canines stimulated uninjured teeth. Tooth mobility was measured with the Periotest® device. Vertical and horizontal measurements were made before and after splinting, and the difference between values was defined as the splint effect. We evaluated 4 composite splints, 3 wire‐composite splints, a titanium trauma splint, a titanium ring splint, a bracket splint, and 2 Schuchardt splintsResults: For all injured teeth and all splints, there was a significant splint effect for the vertical and horizontal dimensions (P < 0.05). For injured teeth, the composite splints produced the largest changes in vertical tooth mobility; wire‐composite splints 1 and 2, using orthodontic wires, produced the smallest vertical splint effects. For uninjured teeth, the Schuchardt 1 splint and the bracket splint produced the largest splint effects; wire‐composite splints 1 and 2 produced only a slight change in tooth mobility. Composite splints 2 and 3 produced the largest horizontal splint effects for injured teeth, and the 4 composite splints produced the largest horizontal splint effects for uninjured teeth. The most horizontally flexible splints were the titanium trauma splint and wire‐composite splints 1 and 2.Conclusions: According to the current guidelines and within the limits of an in vitro study, it can be stated that flexible or semirigid splints such as the titanium trauma splint and wire‐composite splints 1 and 2 are appropriate for splinting teeth with dislocation injuries and root fractures, whereas rigid splints such as wire‐composite splint 3 and the titanium ring splint can be used to treat alveolar process fractures.Keywords
This publication has 22 references indexed in Scilit:
- Comparison of a new dental trauma splint device (TTS) with three commonly used splinting techniquesDental Traumatology, 2001
- Splinting of traumatized teeth with a new device: TTS (Titanium Trauma Splint)Dental Traumatology, 2001
- Splints made of wire and composite: an investigation of lateral tooth mobility in vivoDental Traumatology, 1995
- Rigidity of various fixation methods used as dental splintsDental Traumatology, 1992
- Tooth splinting: a review of the literature and consideration of the versatility of a wire‐composite splintDental Traumatology, 1990
- Functional fixation for traumatically luxated teethDental Traumatology, 1987
- Effect of masticatory stimulation on dentoalveolar ankylosis after experimental tooth replantationDental Traumatology, 1985
- The effects of different splinting times on replantation of teeth in monkeysOral Surgery, Oral Medicine, Oral Pathology, 1982
- Technique and Rationale for SplintingThe Journal of the American Dental Association, 1980
- The effect of splinting upon periodontal healing after replantation of permanent incisors in monkeysActa Odontologica Scandinavica, 1975