Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging
Authors:
- Hwan KooHKHwan Koo
- Kyung Heon LeeKLKyung Heon Lee
- Sang Min KimSKSang Min Kim
- Jeehyun LeeJLJeehyun Lee
- Sung Wan KimSKSung Wan Kim
- Jin Keun SeoJSJin Keun Seo
- Eung Je WooEWEung Je Woo
- 11 February 2008
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (3) , 295-307
Abstract
Validation and interpretation of reconstructed images using a multi-frequency electrical impedance tomography (mfEIT) requires a conductivity phantom including imaging objects with known complex conductivity (sigma + iomegaepsilon) spectra. We describe imaging experiments using the recently developed mfEIT system called the KHU Mark1 with the frequency range of 10 Hz to 500 kHz. Using a bio-impedance spectroscopy (BIS) system, we first measured complex conductivity spectra of different imaging objects including saline, agar, polyacrylamide, TX151, animal hide gelatin, banana and cucumber. Based on an analysis of how conductivity and permittivity affect measured complex boundary voltages, we suggested a new complex version of a multi-frequency time-difference image reconstruction algorithm. Imaging experiments were conducted to produce time-difference images of the objects at multiple frequencies using the proposed algorithm. Images of a conductor (stainless steel) and an insulator (acrylic plastic) were used to set a common scale bar to display all images. Comparing reconstructed time-difference images at multiple frequencies with measured complex conductivity spectra, we found that they showed an overall similarity in terms of changes in complex conductivity values with respect to frequency. However, primarily due to the limitation of the difference imaging algorithm, we suggest that multi-frequency time-difference images must be interpreted in terms of relative contrast changes with respect to frequency. We propose further imaging studies using biological tissues of known complex conductivity spectra and using human subjects to find clinical applications of the mfEIT system.Keywords
This publication has 16 references indexed in Scilit:
- Calibration methods for a multi-channel multi-frequency EIT systemPhysiological Measurement, 2007
- Multi-frequency EIT system with radially symmetric architecture: KHU Mark1Physiological Measurement, 2007
- Design and implementation of a high frequency electrical impedance tomography systemPhysiological Measurement, 2004
- A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arraysIEEE Transactions on Biomedical Engineering, 1999
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- Use of a modified polysaccharide gel in developing a realistic breast phantom for MRIMagnetic Resonance Imaging, 1996
- Conductivity and permittivity images from an induced current electrical impedance tomography systemIEE Proceedings - Science, Measurement and Technology, 1994
- NOSER: An algorithm for solving the inverse conductivity problemInternational Journal of Imaging Systems and Technology, 1990
- Tissue‐mimicking gelatin–agar gels for use in magnetic resonance imaging phantomsMedical Physics, 1988
- The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologistMedical & Biological Engineering & Computing, 1967